ENFORCER Slimline Illuminated Square Request to Exit Plates
Wiring for SD-7103GC-PTQ:
1. Connect the RED wire to the "+" spade connector and the BLACK wire to the "-" spade connector (see
Fig. 1).
2. Connect 12~24 VAC or VDC (non-polar) to the power input terminal block of the timer module (see
Fig. 3).
3. Connect a N.O. or N.C. device to the relay output terminal block as desired.
4. Connect the positive and negative wires of the buzzer to the buzzer output terminal block if desired.
5. Set the timer module between 1~180 s via the trimpot as shown. Turn clockwise to increase and
counterclockwise to decrease. Test to ensure the timer is set correctly.
6. Complete installation as directed in the "Installation:" on page 2.
Figures:
Figure 1 - Wiring
Green wire for N.C.
Red wire for LED*
Blue wire for N.O.
*IMPORTANT: For 24VDC operation, use the included 680Ω, 0.5W resistor in line with the red wire or the black wire.
Figure 2 – Removing the Switch
A. Plastic
Protector
B. Plastic Nut
C. Rubber O-ring
D. Lens Access
Holes
E. Rubber Seal
F. Message Plate
G. Lens
Figure 3 – Timer Outputs
Timer Adjustment
Trimpot
To adjust time (1~180
sec.), turn trimpot
clockwise to increase,
counterclockwise to
decrease.
SECO-LARM U.S.A., Inc.
(with timer module)
1
+
4
A
B
C
Timer Module
Top View
NOTE: Terminal legend can be found on back of PCB.
Relay rated 3A@24VDC
2
Blue wire for N.O.
3
Black wire for LED*
-
2
Green wire for N.C.
(–)
Buzzer
(+)
Output
(N.C.)
(N.O.)
Relay
Output
2
(COM)
(COM)
Trigger Input
(N.C.)
(Factory prewired)
(N.O.)
Power Input 12~24 VAC
or VDC (non-polar)
D
E
F
G
3