Télécharger Imprimer la page

ENFORCER SD-7103GC-PEQ Mode D'emploi page 2

Publicité

Les langues disponibles

Les langues disponibles

ENFORCER Slimline Illuminated Square Request to Exit Plates
Features:
 Square illuminated push button with caption
"PUSH TO EXIT"
 Message language can be easily changed in the
field to Spanish or French
 CE and UL approved switch is rubber-sealed to
prevent liquid penetration
 Weather resistant when properly installed
 Includes stainless-steel slimline plate
 Includes six colored 12-inch wire leads with easy-
to-attach spade lugs for fast installation
Installation:
(for SD-7103GC-PTQ please see next page)
1. Run four wires through the wall to a slimline back-box:
a. Two wires, 12VDC or 24VDC, for the light.
b. Two wires each from the N.O. and/or N.C. terminals of an alarm or access control system which can
unlock an electrically controlled lock.
2. Connect four colored wires (included) to the switch as below (see fig. 1):
a. RED wire to the brass-colored spade connector marked "+".
b. BLACK wire to the brass-colored spade connector marked "-".
c. GREEN wires to the N.C. connectors marked "1" and "2" (if needed).
d. BLUE wires to the N.O. connectors marked "3" and "4" (if needed).
3. Connect the colored wires to wires from the alarm or access control system, and to the light's power
source (see fig. 1):
a. RED and BLACK wires – To a 12VDC or 24VDC source. For 24VDC operation, connect the
supplied 680Ω, 0.5W resistor inline with either the red or black wire.
b. GREEN wires – To the N.C. terminals of the alarm or access control system (if needed).
c. BLUE wires – To the N.O. terminals of the alarm or access control system (if needed).
4. For weatherproof installation, use a waterproof backbox and apply a bead of silicone sealant (not
included) around the rim of the backbox and faceplate edge. Apply a small amount of sealant below each
screw head.
5. Screw the plate into the back-box, taking care not to crimp the wires and ensuring a good seal.
Changing the Message Plate:
NOTE: This should be done before connecting any wires.
1. If the steel plate is already mounted, it must be removed from the mounting surface.
2. Disassemble the switch as follows (see fig. 2):
a. Pop off the clear plastic protector (A) at the rear of the switch assembly.
b. Unscrew the black plastic nut (B) holding the assembly together.
c. Remove the small black rubber O-ring (C).
d. Separate the switch assembly from the slimline steel plate.
3. Insert the end of a large paper clip or other similar wire into any of the four corner holes (D) found at the
back of the black switch housing until the green switch lens (G) pops off.
4. Replace the "PUSH TO EXIT" message plate (F) with the language of choice. Be careful not to lose the
rubber seal (E). Make sure the message plate direction is correct.
5. Snap the lens back on and reassemble the switch and plate assembly, installing as directed above.
2
 Long-life green LED 12/24 VAC/VDC (Approx.
35,000 hrs)
 SD-7103GC-PEQ Includes:
- Momentary switch, DPST, NO/NC contacts
rated 5A@250VAC max.
 SD-7103GC-PTQ Includes:
- Timed output from 1~180 s
- SPDT Switch rated 3A@24VDC
- Buzzer output for audio status
SECO-LARM U.S.A., Inc.

Publicité

loading

Ce manuel est également adapté pour:

Sd-7103gc-ptq