Features
Battery Backup/Surge Protected Outlets: These outlets offer battery backup support and premium surge suppression for critical
8
devices requiring battery backup support.
Note: Do not plug laser printers into the battery backup outlets.
Battery Backup/Surge Protected ECO Outlet: This outlet provides battery backup support and surge and noise protection. Your UPS
9
system can save energy by automatically turning off this outlet when it detects your computer is turned off or in standby mode. Make
sure that any devices connected to the ECO outlets can be turned off without interrupting your Internet connection, local network or other
essential services. See the ECO Energy-Saving Feature section for more information.
Surge-Only Protected Outlets: Provide surge and line noise protection, not battery backup or the ECO feature. Plug equipment that does
10
not require battery backup during a utility power failure into these outlets, such as a printer, scanner or fax machine.
Surge-Only Protected ECO Outlet: These outlets provide surge and noise protection, but not battery backup. Your UPS system can save
11
energy by automatically turning off these outlets when it detects that your computer is turned off or in standby mode. Make sure that any
devices connected to the ECO outlets can be turned off without interrupting your Internet connection, local network or other essential
services. See the ECO Energy-Saving Feature section for more information.
Resettable Input Circuit Breaker: Protects your electrical circuit from over current draw from the UPS load. If this breaker trips, remove
12
some of the load, then reset by pressing it in. Breaker is rated for 15A, 250V AC.