Gb Installation Instructions; System Components; Safety Instructions - STEINEL IR180UP Instructions De Montage

Masquer les pouces Voir aussi pour IR180UP:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12

GB Installation Instructions

Dear Customer,
Congratulation on purchasing your
new STEINEL Sensor Switch and
thank you for the confidence you
have shown in us. You have chosen
a high-quality product that has been
manufactured, tested and packed with
the greatest care.

System components

IR 180 UP:
a Flush box
b Basic element
c Cover frame
d Surround
e Sensor unit
f Button for permanent light and
permanent light OFF
g Permanent light and permanent
light OFF indicator (red LED
behind lens)
h Catch (Design shade for
function adjustment, folding)
i Twilight setting
2 - 2000 lux
j Time setting
5 sec. - 30 min.

Safety instructions

n Disconnect the power supply before
any work on the Sensor Switch!
n During installation, the electric
power cable to be connected must
be voltage-free. Therefore, switch
OFF the power first and check
freedom from voltage with a voltage
tester.
Please familiarise yourself with these
instructions before attempting to in-
stall the Sensor Switch as prolonged
reliable and trouble-free operation will
only be ensured if it is fitted correctly.
We hope your new Sensor Switch will
give you lasting satisfaction.
HF 360 UP:
a Flush box
b Basic element
c Cover frame
d Surround
e Sensor unit
f Button for permanent light and
permanent light OFF
g Permanent light and permanent
light OFF indicator (red LED)
h Catch (Design shade for
function adjustment, folding)
i Twilight setting
2 - 2000 lux
j Time setting
5 sec. - 30 min.
k Reach setting
1 - 8 m
n Installation of the Sensor Switch
involves work on the mains power
supply; this work must therefore be
carried out professionally in accord-
ance with regulations.
(DE - VDE 0100, AT - ÖVE-EN 1,
CH - SEV 1000)
- 14 -
Principle
With the IR 180 UP and HF 360 UP
sensor switches, groping for the light
switch is finally a thing of the past!
The intelligent sensor technology
switches the light ON automatically
IR 180 UP:
8 m
max.
Angle of coverage: 180°
The IR 180 UP is equipped with a pyro
sensor which detects the invisible
heat emitted by moving objects (pe-
destrians, animals etc.). The heat thus
detected is electronically converted
and switches ON connected consum-
ers (e.g. a light). No heat radiation is
detected through obstacles, such as
walls or glass and no switching there-
fore occurs.
on entering the room and OFF again
after the preset time. This is not
only extremely convenient, but also
increases safety and is energy and
cost saving.
HF 360 UP:
8 m
max.
Angle of coverage: 360°
The HF 360 UP is an active motion
detector. It reacts independently of
temperature to the slightest move-
ment. The integrated HF sensor trans-
mits high frequency electromagnetic
waves (5.8 GHz) and receives their
echo. In response to the slightest
movement in the detection zone, the
change in echo is perceived by the
sensor. A microprocessor subsequent-
ly triggers almost without delay the
switching command "light ON".
Detection is possible through doors,
panes of glass or thin walls.
- 15 -