PROGRAMMING

MENU DESCRIPTIONS

The menu is used to configure the operator based on your application and the devices that are connected to the operator.
NOTE: The encoder menu only appears if "Config." is selected from the "Functions" menu.
MAIN MENU
SUB MENU
LANGUAGE
English
Francais
Deutsch
Espanol
Italiano
FUNCTIONS
AutoClose
Maintained Act
Obstacle Det.
Safety Test
Preflashing
Ram hit funct.
Total Stop
CX Input
CY Input
CZ Input
CI. Thrust
Lock
Config.
endstop
cmd 2-7
cmd 2-3P
The language menu determines the language for the menu. Factory default is Italian.
Select for English
Select for French
Select for German
Select for Spanish
Select for Italian
The functions menu determines how your operator will function.
Automatic Close: Activates or deactivates the automatic close timer (ACT). The automatic close timer (ACT) activates at each opening
endpoint. The time may be adjusted, and is dependent on any entrapment protection devices that may activate; and it does not activate after
a total safety "stop" or during a power outage.
Maintained Action: The gate works by constant pressure to open (button 2-3) and constant pressure to close (button 2-4) or if set to the
"On Closing" function, only button 2-4. (Remote Control functionality is disabled).
Obstacle Detected: When motor is stopped (gate closed or after a total stop command) it prevents any movement if an entrapment
protection devices, such as the photoelectric sensors, detect an obstacle.
Safety Test: Allows the electronic card to check the efficiency of any entrapment protection devices (i.e. photoelectric sensors) after every
open or close command.
Pre-Flashing: After an opening or closing command, the flashing light, connected to 10-5, starts flashing before the gate begins to
run. Pre-flashing can be enabled using the FUNCTIONS menu and the timing period can be set using the TIMING ADJ menu, however,
when the gate is closed and pre-flashing is enabled the opening will be delayed for the duration of the pre-flashing period but the
light will not start flashing until the gate starts moving.
Ram Blow: Before opening the gate(s) will press onto the mechanical endstop for a few seconds, to help release the electrolock (to set the
time, see "Ram timing" in the Adjust Timings menu).
Total Stop: This function stops the gate and consequently excludes any automatic closing cycle; for movement to Resume, you need
to use the keypad or remote control. Insert entrapment protection device on [1-2] if used, select "Deactivated" if unused.
CX Input: The N.C. safety contact input can take on the following functions: C1 (re-opening when closing), C2 (re-closing when
opening), C3 (partial stop), C4 (obstacle stall), C7 (re-opening when closing, for sensitive edges), C8 (re-closing when opening, for
sensitive edges) or, be deactivated. Refer to entrapment protection devices.
CY Input: Safety contact input can take on the following functions: C1 (re-opening when closing), C2 (re-closing when opening), C3
(partial stop), C4 (obstacle stall), C7 (re-opening when closing, for sensitive edges), C8 (re-closing when opening, for sensitive edges)
or, be deactivated. Refer to entrapment protection devices.
CZ Input: Safety contact input can take on the following functions: C1 (re-opening when closing), C2 (re-closing when opening), C3
(partial stop), C4 (obstacle stall), C7 (re-opening when closing, for sensitive edges), C8 (re-closing when opening, for sensitive edges)
or, be deactivated. Refer to entrapment protection devices.
Closing thrust: At the endpoint stage during closing, the gearmotors perform a final closing-thrust of the doors for a few seconds.
Lock: To lock the gate(s).
Configuration:
- Encoder: Managing decelerations, obstacle detection and sensitivity (default function): (AX3024U, AX5024U, FROG-A24E, A1824U, FROG-
JU, F7024E)
- Slow run: Decelerations when opening and closing.
- Fcap-RallCh.: End stop when opening and deceleration when closing.
- Time of Run: Timed end stop.
- Limit switch (endstop): Opening and closing endstop.
Endstop: Configure the endpoints are normally closed or open contacts. NOTE: This function appears only if selected from the "Config."
function in the FUNCTIONS menu.
Command 2-7: Setting the 2-7 contact to step-by- step mode (open-close) or sequential (open-stop-close-stop).
Command 2-3P: Setting the 2-3P contact to pedestrian opening (second gate opens fully) or partial (second gate opens partially
depending on the time set on "Partial opening" from the Adjust Times menu).
DESCRIPTION
21