HE240, HE280 HUMIDIFIER AND INSTALLATION KIT
Make sure the humidifier housing is
7.
level, then position it in the opening
so the plastic tabs are in place on the
lower sheet metal edge of the
opening. Use pliers, as necessary, to
flatten cut edges. See Fig. 5.
Secure the humidifier housing to the
8.
opening at the top and bottom using
sheet metal screws.
Use the 6 in. (155 mm) starter collar
9.
as a template to mark the opening for
the bypass. The starter collar end can
be identified by the pliable metal tabs.
Carefully cut the opening for the 6 in. (155 mm) starter collar end of the 48 in.
10.
(1.22 m) flex duct. See Fig. 6. Use a drill to start the cut in the middle of the
circle. Cut in an outward spiral to assist in controlling the cut.
69-2686EF—03
6 IN. ROUND TEMPLATE
STARTING
HOLE
Fig. 6. Cutting bypass opening.
SHEET METAL
SCREWS (4)
PLASTIC
TABS (2)
DRAIN TUBING
Fig. 5. Installing humidifier on duct.
M20172
8
DUCT
LEVEL
OPENING
TO AIR DUCT
M33324