Table 4. Troubleshooting Humidifier. (Continued)
Low
Furnace blower
humidity
not operating.
Rapid air
changes. Drafts
(cold air is dry
and is an added
load to the
humidifier).
Damper in
"summer"
position
High
Condensation
humidity
on walls.
Heavy
condensation on
windows.
HE240, HE280 HUMIDIFIER AND INSTALLATION KIT
Reset circuit breaker or check for blown fuse.
Check that the furnace power is on.
Check all external wiring connections.
Check the humidity control setting.
Verify that pressure switch tubing isn't pinched
or obstructed.
Call a professional heating contractor.
Keep doors and windows closed.
Close fireplace damper when not in use.
Keep exhaust fan running time to a minimum.
Seal around doors and windows.
Set damper blade to "winter" position to allow
humidification.
Turn off humidity control and water until
condensation is completely evaporated.
Turn humidity control down low enough to
eliminate condensation caused by moisture
from bathing, mopping, cooking, etc. If
moisture persists, more ventilation is needed.