HE240, HE280 HUMIDIFIER AND INSTALLATION KIT
WIRING
CAUTION
Hazardous Voltage.
Can cause personal injury or equipment damage.
Disconnect power supply before installing or servicing equipment.
IMPORTANT
All wiring must comply with applicable local code, ordinances and regulations.
Wire the humidifier solenoid valve, humidistat and transformer. See Fig. 16.
Determine the length of wire necessary to run from the humidifier to the
1.
humidistat. Cut to length and strip the ends appropriately.
Connect the red and white wires to the leads on the humidistat per the wiring
2.
diagram. Use the provided wire nuts to secure the connections.
Taking the opposite end of the wire, connect RED WIRE to one terminal on the
3.
humidifier. Leave the white wire loose at this point.
Using remaining wire, determine length needed to run from humidifier to the
4.
transformer. Cut to length and strip the ends appropriately.
Unplug the transformer. Connect the red and white wires to the transformer by
5.
loosening the screws on the transformer, wrap wire around screw post and then
re-tighten the screws.
Taking the opposite end of the wire, connect the RED WIRE to the open
6.
remaining loose terminal on the humidifier.
Connect the remaining two white wires together using the provided wire nut.
7.
69-2686EF—03
HUMIDIFIER
SOLENOID
6
VALVE
RED
RED
WIRE
WIRE
Fig. 16. Wiring the controls and the HE240.
WIRE NUT
RED WIRE
HUMIDIFIER
SOLENOID
VALVE
RED WIRE
Fig. 17. Wiring the controls and the HE280.
HUMIDISTAT
WIRE NUT
WIRE NUT
2
WHITE WIRE
RED WIRE
TRANSFORMER
1
3
WHITE WIRE
7
RED WIRE
WIRE NUT
4
WHITE WIRE
HUMIDISTAT
WIRE NUT
WHITE WIRE
RED
TRANSFORMER
WIRE
WHITE WIRE
WIRE NUT
RED WIRE
WHITE WIRE
14
5
WHITE WIRE
M33413A
WHITE WIRE
M33327A