Transport And Storage - Bosch Rexroth IMpnio Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29
3 609 929 B64/2008-05 | IMpnio
The MS LED indicates the interface module
status.
Table 4 MS
LED display
Meaning
Off
No voltage or not initialized,
module in "SETUP" or
"NW_INIT" status
Green
Module ready for operation,
module not in "NW_INIT"
status
Flashing green
Diagnostic events available
(Flashes once:
...)
Flashing green
Network configuration with
(Flashes twice:
module identification
running
...)
Red
Exception error, module in
"EXCEPTION" status
Flashing red
Configuration error
(Flashes once:
...)
Flashing red
Error in the IP address or
(Flashes twice:
IP address not assigned
...)
Flashing red
Error in station name or
(Flashes three times:
station name not assigned
...)
Flashing red
Severe internal error
(Flashes four times:
...)
Bosch Rexroth AG
5

Transport and storage

For storing and transporting the product
always observe the ambient conditions
specified in the technical data (see
"Technical data" on page 27).
21/84

Publicité

Table des Matières
loading

Table des Matières