IDRODUE 27 - MEASUREMENT OF THE OIL LEVEL AND TOPPING UP
8,5
cm
INSERTION DEPTH
INSIDE THE
DISTRIBUTOR
The oil level should
be measured
with the
ro d inse rte d into the
operator and must stand
in accordance
with the
distributor
IF OPERATORS MUST BE DELIVERED, DON'T APPLY THIS PROCEDURE
1
OIL
CAP
5,5
cm
OPTIMAL LEVEL
BELOW WHICH IT IS
NECESSARY TO TOP
UP THE OIL
IDRO 39 - OIL LEVEL MEASUREMENT
STRIPPING PROCEDURE
TO DO ONLY DURING INSTALLATION
23
2
8,5
cm
OPTIMAL LEVEL
5,5 cm
MAX
IN CASE OF TOPPING UP, KEEP
THE OPERATOR IN A VERTICAL
POSITION AND WITH THE STEM
FULLY INSERTED