OPERATOR INSTALLATION
According to the chosen opening type (inside or outside) and according to the chosen max.
rotation of the leaf, the bracket must be first cut respecting the mesurment "a" and than
welded as in Fig. 2.
The support must be positioned so that the operator is in perfect horizontal position.
Attention: do not use the hammer to insert the short brass pivot; the insertion of the pivot
into the fork and bracket must be made simply by hand pressure (Fig. 3).
Attention: do not incline the hydraulic operator further then the allowed angle from the
oscillating fork (1), could cause the braking of it (1) (Fig. 4).
58 mm
b
(1)
c
a
Livella
(1)
3
Parts to install according to EN 12453 standard
COMMAND TYPE
Hold-to-run operation
Impulsive - in sight
(e.g. push-button)
impulsive - out of sight
(e.g. remote)
Livella
automatic
* a typical example are those doors which do not have access to any public way
A: Hold-to-run operation made by push-button ex: code ACG2013
B: Hold-to-run operation made by key selector ex: code ACG1010
C: Adjustable power of the motor or photocells to respect impact forces as indicated in
Annex A
D: Safety strips and/or other additional devices to reduce the probability of contact with
the door.
E: Devices installed in such a way that a person can not be touched by the door.
IDRODUE 27
Total stroke 270 mm - Max. recommended stroke 250 mm - d ~ 970 mm
a
b
100
115
100
150
105
110
105
145
120
105
2
120
130
125
125
140
95
140
110
145
95
145
105
150
100
155
85
160
90
170
75
180
65
IDRO 39
4
Total stroke 390 mm - Max. recommended stroke 370 mm - d ~ 1210 mm
a
b
125
170
130
170
140
235
145
165
145
230
160
210
175
195
185
145
185
190
195
140
195
175
240
110
240
125
250
105
250
115
260
95
260
100
270
90
280
80
295
65
If the pillar is too large, and it is not possible to adjust the operator respecting the measure
5
a, you must make a niche in the pillar or you have to move the gate to the edge of the pillar.
20
USE OF THE SHUTTER
Skilled persons
Skilled persons
(out of public area*)
(public area)
A
B
C or E
C or E
C or E
C and D, or E
C and D, or E
C and D, or E
c (max)
Max. Opening
Max. Stroke
50
110°
250
50
90°
55
110°
245
55
90°
70
105°
250
70
90°
75
90°
90
100°
250
90
90°
95
100°
255
95
90°
100
90°
105
95°
250
110
90°
120
90°
130
90°
c (max)
Max. Opening
Max. Stroke
75
125°
368
80
125°
372
90
90°
95
120°
372
95
90°
110
90°
120
90°
130
110°
370
130
90°
140
110°
371
140
90°
185
100°
370
185
90°
195
95°
370
195
90°
205
95°
369
205
90°
215
90°
230
90°
245
90°
Measurements in mm
Not skilled
persons
Not possible
C and D, or E
C and D, or E
C and D, or E
Stroke for 90°
215
250
215
250
225
250
250
235
250
242
250
250
242
253
250
250
Stroke for 90°
295
300
370
310
370
370
370
330
370
355
370
355
370
360
370
365
370
370
370
369

Publicité

Table des Matières
loading

Table des Matières