APPLIANCE INSTALLATION

Safety Information

• If this stove is not properly installed, a house fire or smoke spillage may result. To reduce the risks,
follow the installation instructions.
• Do not use makeshift materials or make any compromises when installing this appliance.
• This stove is mobile home approved and in these cases requires installation of a fresh air kit,
sold separately. The stove must be attached to the structure of the mobile home and the structural
integrity of the mobile home floor, wall, and ceiling / roof must be maintained. Do not install in a
sleeping room of a mobile home.
• This stove must be connected to a standard 120V / 60Hz, grounded electrical outlet. Do not use
an outlet adapter, an extension cord or sever the grounding plug. Do not route the electrical cord
underneath, in front or over the stove.
• This stove is not recommended to be installed in a bedroom.
• Burning any solid fuels generates carbon monoxide in low concentration. This gas is evacuated
by the exhaust venting system. In higher concentrations, carbon monoxide is toxic and may
cause death. To prevent this, ensure that the exhaust venting system is airtight and installed
properly.
• A smoke detector, a carbon monoxide detector and a fire extinguisher should be installed in the
house. The location of the fire extinguisher should be known by all family members.
This product can expose you to chemicals including carbon monoxide, which is
known to the State of California to cause cancer, birth defects or other reproductive
harm. For more information go to

Regulations

• When installed and operated as described in these instructions, this pellet stove is suitable for use
as a freestanding heater in residential installations.
• In Canada, the CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment and
the CSA C22.1 Canadian National Electrical Code are to be followed in the absence of local code
requirements.
• In the USA, the ANSI NFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning
Appliances and the ANSI NFPA 70 National Electrical Code are to be followed in the absence of
local code requirements.
• This stove must be connected to a pellet venting system complying with the requirements for Pellet
Vent UL 103, UL 641, ULC S629M, CAN/ULC S609 and ULC/ORD C441 standards or to a code-
approved masonry chimney with a stainless steel flue liner.
Installation Manual - 3000