Note: We recommend that you do not put regenerant into the
tank until after the control valve has been put into operation.
With no regenerant in the tank, it is much easier to view water
flow and motion in the tank.
8. Press and hold the SET and UP button for five seconds to
cancel regeneration, and cycle the control back to the service
position.
9. Start another regeneration. Advance the controller to the brine
refill position (C8) to prime the line between the regenerant
tank and the valve (conditioner only).
A. Slowly open the main water supply valve again to the
fully open position. Be sure not to open too rapidly, as
that would push the media out of the media tank.
Note: As you advance through each cycle, there will be a slight
delay before you can advance to the next cycle. There will be
a pause after the brine draw and slow rinse cycles (system
pause). This cycle allows the water/air pressure to equalize on
each side of the valve discs.
B. With the water supply completely open, when you
arrive at the brine tank refill cycle, the controller will
direct water down through the line and into the tank.
Watch the bottom of the tank until all air bubbles
have been purged from the line and the water level
is rising.
C. Let the water flow down the line to the tank only until
the rising water is visible.
D. Simultaneously press and release the SET and UP
buttons to advance to the Brine Make-up cycle. After
the Brine Make-up cycle is reached, press the SET
and UP buttons to advance to the Brine Draw/Slow
Rinse cycle.
10. Draw water from the regenerant tank.
A. With the controller in this position, check to see that
the water in the regenerant tank is being drawn out
of the tank. The water level in the tank should recede
very slowly.
B. If the water in the regenerant tank does not recede,
or goes up, refer to the Troubleshooting section.
11. If the water level is receding from the regenerant tank, wait
for the tank check valve to stop the water flow. Press the SET
and UP buttons to advance the controller back to the treated
water position.
12. Finally, turn on a faucet plumbed after the water conditioner.
Run the faucet until the water runs clear.
The Water Conditioning System
is Now Fully Operational.

Manual Regeneration Options

The Analyzer control features several options that offer additional
flexibility for manually regenerating the conditioner.
Delayed Manual Regeneration
Pressing and releasing the REGEN button starts a delayed manual
regeneration. The Regeneration icon on the display will flash
indicating a regeneration will start when the time of day reaches
the programmed time of regeneration. Pressing the REGEN button
again will turn off the regeneration icon and cancel the delayed
regeneration.
Immediate Manual Regeneration
Pressing and holding the REGEN button for three seconds starts
an immediate manual regeneration. A solid regeneration icon will
be displayed. The control will immediately begin a regeneration.
Delayed Second Regeneration
Pressing and releasing the REGEN button while the control is
in regeneration will program the control for a delayed second
regeneration. A flashing x2 icon next to the regeneration icon will
appear, indicating a second regeneration will start when the time
of day reaches the programmed time of regeneration.
Double Immediate Manual Regeneration
Back-to-Back manual regenerations are initiated by pressing and
holding the REGEN button for three seconds while the control is
in the regenerating mode. A solid x2 icon next to the regeneration
icon will appear, indicating a second manual regeneration will
start immediately after current regeneration is complete.