Télécharger Imprimer la page

3B SCIENTIFIC PHYSICS U21910 Mode D'emploi page 8

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
6.2 Circular waves
Depending on the choice of the desired waves,
press 1 to 3 dippers onto the edge of the wave
exciter, pressing either briefly or for a lengthier
period as required.
With the help of the knurled screws, attach the
wave exciters to the vibrator.
Set the depth of immersion by setting the vi-
brator so that the lower edge of the exciter
touches the water surface in a straight plane.
On the control unit, set the desired frequency
and amplitude.
On the viewing screen, a stationary or slowly
moving wave pattern can be observed. Make
fine adjustments using the turning knob.
6.3 Determining the wavelength
When determining the wavelength, the magnifica-
tion factor b must be taken into account.
Magnification factor b can be calculated by placing
the biconcave lens onto the ripple tank for instance
and checking the ratio of its actual size A to the size
of its projection on the viewing screen A'.
b = A'/A
The actual wavelength λ can be calculated from the
wavelength λ' measured on the viewing screen as
follows.
λ = λ'/b
7. Storage and maintenance
Store the ripple tank in a dust-free place.
Thoroughly dry the ripple tank after use to
prevent it developing water stains and lime
scale deposits.
3B Scientific GmbH • Rudorffweg 8 • 21031 Hamburg • Germany •
Subject to technical amendments
© Copyright 2009 3B Scientific GmbH
www.3bscientific.com

Publicité

loading