Before commencing with the installation of this appliance make sure that you have read the following
instructions carefully. In particular familiarise yourself with the safety devices required by the system,
only then will you be able to use them to great effect.
Not all of the safety devices required by the safety standards have been taken into consideration in this
manual. The installer must make sure that any eventual safety devices required by the local standards
and regulations have been installed both ahead of and after the products described in this manual.
This appliance must be used exclusively for the purpose for which it has been made. Any non
authorised modifications are to be considered improper and therefore dangerous. The manufacturer
accepts no liability for damage caused by, or situations arising from, the improper use of these
appliances and therefore all work carried out after the delivery of the appliance is to be considered
the complete responsibility of the installer.
These instructions are aimed at professionally qualified "installers of electrical equipment" in
conformity with the local standards in force.
Description
- the electronic components consist of a mother board with an extractable logic card inserted into one of
the interface slots.
- all weather container in ABS with a stainless steel hinged inspection door (180° opening angle), door
sealing gasket (IP 55)
- lockable inspection door with security mains switch
- container fitted with wall fastening elements
- power cable inlet complete with cable clamp
- low power terminal board connections
- radio control receiver interface
- external control buttons (available on request)
INSTALLATION INSTRUCTIONS
Technical specifications
Threephase power supply
Frequency
Motors
Maximum power consumption motors (threephase)
Short circuit current with fuses
Nominal current input
Operating temperature
Protection grade
Protection grade with external control buttons
Fire protection grade
Container fitted with cable clamps for Ø16 mm pipes
The PRG384 kit contains:
- The programmer PRG384
- A series of wall mounting screws etc.
- Nr. 2 keys
- The instruction manual
Positioning
Depending on the type of installation work out the position in which the programmer will be situated
remembering that the site must be:
- a position safe from accidental collision
- high enough above the ground to be safe from pools of water
- in a position which the technician can easily reach.
REMARKS
8
ENGLISH
Vac
400V3~
Hz
Nr.
W
Amp.t<300 ms
Amp
°C
-20...+55
IP
IP
UL94
50-60
1
2200
20
5
55
54
V0