Abus HomeTec Z-Wave CFA3010 Instructions De Montage Et D'utilisation page 28

Mécanisme de serrure
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 48
with a key permanently inserted
in the lock, the cylinder must have
an "emergency" feature where the
door can be opened with a key from
the outside even when another key
is inserted on the inside. In additi-
on, the door lock must be a profile
cylinder compliant with DIN 18252.
Prepare for Installation / Reset
Please read this user manual before
installing the product.
In order to include (add) a Z-Wa-
ve device to a network it must
be in factory default state. Please
make sure to reset the device into
factory default. You can do this by
performing an Exclusion operation
as described below. Every Z-Wave
controller is able to perform this
operation however it is recommen-
ded to use the primary controller of
the previous network to make sure
the very device is excluded properly
from this network.
Installation
A particular plus point is that the
device can be built in without
needing to use a special cylinder. So
you can integrate it into an existing
locking system. The only require-
ment is that the door cylinder must
be a cylinder with an emergency
and danger function. This function
is extremely important. As it ensures
that you can unlock your front
door with your normal house key,
when required. In addition, there
should be a cylinder projection of
at least 7 to max. 12 millimetres on
the inside so that the HomeTec Pro
can be built in quickly without any
problems.
Enable Fallback to S0 Security
If your Z-Wave Gateway/Controller
does not support the S2 standard,
inclusion is not possible immedia-
tely. To perform an inclusion, the S0
standard must be activated manual-
ly. (Since the Z-Wave S0 standard
has a minimal security risk during
teach-in, it is deactivated by default
for the entry solution). Press the
28
CFA3010 Z-Wave6.indd 28
two arrow keys for 3 seconds until
the left LED lights up green. This
indicates the management mode.
Press both arrow keys again for 3
seconds until the left LED flashes
green. Now press the „up" arrow
key; the left LED flashes red. Confirm
with the „Close" key. The left LED
flashes red, the right one lights up
green = Standard S2. Press the down
arrow key; the left LED flashes red
and the right lights up red = S0
Security. Confirm the change from S2
to S0 by pressing the Close" key.
Inclusion/Exclusion
On factory default the device does
not belong to any Z-Wave network.
The device needs to be added to
an existing wireless network to
communicate with the devices of
this network. This process is called
Inclusion.
Devices can also be removed from
a network. This process is called
Exclusion. Both processes are ini-
tiated by the primary controller of
the Z-Wave network. This controller
is turned into exclusion respecti-
ve inclusion mode. Inclusion and
Exclusion is then performed doing a
special manual action right on the
device.
Process:
1. At first switch the primary Z-Wave
controller to Inclusion or
Exclusion mode
2. Now press the two arrow keys on
the drive for 3 seconds until the
left LED lights up green. This
indicates the management mode.
3. Press the „lock" button to start
in- or exclusion, depending on
what was previously set on the
primary Z-Wave controller.
4. Both LEDs flash green to indicate
that the unit is ready.
5. If the in- or exclusion is success-
ful or if a timeout occurs, the
green LED on the right goes out
and the flashing ends.
Please also note the transcription
of the primary Z-Wave controller.
6. Pressing the „Unlock" button will
09.01.2019 16:19:48