Set-Up Procedure For The Tig Process And Restoring Factory Default Settings (Sth Model Only) - Miller Maxstar 150 S Manuel Du Propriétaire

Masquer les pouces Voir aussi pour Maxstar 150 S:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4-5. Set-Up Procedure For The TIG Process And Restoring Factory Default Settings
(STH Model Only)
5
6
7
8
2
To enter Set-Up Mode, turn power On while
pressing and holding the Process switch pad
for approximately 5 seconds, until the Ready
(3) and High Temp (4) lights flash alternately.
Selectable Features:
Feature 1 − Selectable Trigger Method (Three to choose from):
• Standard trigger − Typically used with a remote amperage con-
trol device. Standard trigger provides non-contact start in DC Im-
pulse TIG mode. It also enables Lift-Arc start, with a remote con-
trol, in Lift- Arc mode.
• Lift-Arc Panel Control − Allows Lift-Arc start without using a
remote control device. Lift-Arc is used when HF starts are not per-
mitted, or to replace scratch starts.
• 2T Trigger Hold − In the HF mode, used with a push button control
device as an on-off switch. In the Lift-Arc mode, using the Lift-Arc
method (see Section 4-4), push and release torch trigger to start
weld. Push and release torch trigger to end weld current and start
Auto Crater. Auto Crater ramps weld current down at a fixed rate
to end the weld cycle.
To change trigger method, enter set-up mode as described above
and illustrated on the next page.
OM-2242 Page 16
1
2
3
4
Feature 2 − Pulse Frequency: Choose from the following four inter-
vals: .5 PPS, 1 PPS, 2.5 PPS, or 60 PPS.
To change pulse frequency, enter set-up mode as described above
and illustrated on the next page.
Restoring Factory Default Settings
To restore factory default settings, press and hold process switch
pad and turn power On. Ready and high temp lights will begin to flash
alternately. Continue holding process switch pad for approximately
10 seconds until the lights begin to flash simultaneously. Release
switch pad, as factory default settings are restored. The lights will
continue to flash until unit is turned Off. To return to normal welding
operation, turn power On.
Factory default settings:
Trigger Methods for Models with Stock No. 907 136-014 only:
TIG Impulse-standard; Lift-Arc-standard
Trigger Methods: TIG Impulse-Standard; Lift-Arc−On
Pulse Frequency - 2.5 PPS
Set-Up Procedure
1
Power Switch
2
Process Switch Pad
3
Ready Light
4
High Temp Light
5
TIG HF Light
6
TIG Pulse Light
7
TIG Lift-Arc Light
8
Stick Light

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Maxstar 150 stlMaxstar 150 sth

Table des Matières