Putting Into Operation; Connecting To Electrical Mains; Environmental Protection Information; Recycling - Dometic miniBar Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
GB

10. Putting into operation

Technical data:
Model
RH 423LDAG
Type
MB20-60
Gross volume
25 litres
Mains operation
220 - 240V (AC)
Input
75W
Energy consumption
1,02 kWh/24h
Climate class
N
Refrigerant
159g H

10.1. Connecting to electrical mains

The appliance may only be operated from
nominal voltage mains as shown on the data
plate. The appliance mains plug may be connected
to a mains socket earthed in accordance with
regulations.
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
The manufacturer declines any liability should
these safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity
supply voltage is the same as that indicated on the
appliance rating plate.
Only for UK:
The appliance is supplied with a 3 Amp plug fitted.
In the event of having to change the fuse in the plug
supplied, a 3 Amp ASTA approved (BS 1362) fuse
must be used. Should the plug need to be replaced
for any reason, the wires in the mains lead are
coloured in accordance with the following code:
Green and Yellow: Earth
Blue:
Neutral
Brown:
Live
The wire coloured green and yellow must be
connected to the terminal marked with the letter "E"
or by the earth symbol
yellow.
The wire coloured blue must be connected to the
terminal "N" or coloured black.
The wire coloured brown must be connected to the
terminal marked "L" or coloured red.
8
RH 439LDAG
MB20-60
29 litres
220 - 240V (AC)
75W
1,1 kWh/24h
N
O+86g NH
147g H
O+98g NH
2
3
2
or coloured green and
RH 449LDAG
MB20-60
37 litres
220 - 240V (AC)
75W
1,2 kWh/24h
N
147g H
O+98g NH
3
2
3
Upon completion there must be no cut, or stray
strands of wire present and the cord clamp must be
secure over the outer sheath.
11. Environmental protection
information
Ammonia
(natural
compound) is used as a refrigerating agent in the
refrigeration unit.
The ozone-friendly cyclopentane is activated as a
motive agent for the PU foam insulation.
Sodium chromate is used for corrosion protection
(less than 2 weight % of the coolant).

12. Recycling

After unpacking the appliance, the packing
materials should be delivered to a local collection
site. At the end of its useful lifetime, the appliance
should be delivered to a specialized collection and
reprocessing firm, which reclaims the usable
materials. The rest is properly destroyed.
Appliances bearing this symbol must be
deposited at the designated local
reception point for the disposal of
electrical and electronic equipment.
It is not permitted that this product be
disposed of by way of the normal
household refuse collection system.
Dometic refrigerators bear this symbol on the
specifications plate (data plate) to be found in the
interior of the unit.
This appliance complies with the following EEC
directives:
LVD-Directive
amendment
EMC-Directive
RoHS - Directive
hydrogen
and
nitrogen
73/23/EEC with
90/683/EEC
89/336/EEC
2002/95/EC