3 C = SLOW RINSE STAGE
IN EQUI-CURRENT
-
In this stage we have pressure in points 4 - 2 of
the pilot control, transmitted to the pistons F - G
in points 4 - 2 of the valve.
-
The black arrows indicate the hard water route,
plus already aspirated brine.
-
The white arrows indicate the slow washing
water route.
-
C = UNTREATED WATER INFEED.
-
B = UNTREATED WATER OUTFEED.
-
E = OPEN DISCHARGE OF SLOW RINSE WATER.
-
A = UNSTABLE VALVE OPEN TO GUARANTEE WATER
TO THE SERVICES DURING THE
REGENERATION STAGES.
4 C = RAPID RINSE STAGE
IN EQUI-CURRENT AND
WATER TRANSFER TO
BRINE TANK
-
In this stage we have pressure in points 4 - 1 of
the pilot control, transmitted to the pistons F - G
in points 4 - 1 of the valve.
-
The black arrows indicate the hard water route.
-
The white arrows indicate the final rapid
washing water route.
-
C =UNTREATED WATER INFEED.
-
B = UNTREATED WATER OUTFEED.
-
E = OPEN DRAIN OF RAPID RINSE WATER.
-
D =WATER TRANSFER TO BRINE TANK.
-
A = UNSTABLE VALVE OPEN TO GUARANTEE
WATER TO THE SERVICES DURING THE
REGENERATION STAGES.
PI LOTA DI COMANDO
CONTROL
PILOT
E
VALVE BODY
CORPO VALVOL A
CONTROL
PI LOTA DI COMANDO
PILOT
CORPO VALVOL A
VALVE BODY
3
1
4
2
B
C
A
F
G
3
2
4
3
1
4
2
B
C
A
E
F
G
3
2
4
29
D
1
D
1