– Cleaning from lifting platform/scaffold:
Clean the modules from top (telescopic
lance extended) to bottom (telescopic
lance retracted).
– Clean larger surfaces in sectors.
– When retracting or extending the tele-
scopic lance, point the stop-cock to-
wards the bottom. This allows for a bet-
ter feeding of the hose.
– Only possible with heated high-pres-
sure cleaners (HDS appliances):
If required, we recommend the use of
the detergent RM 99.
Set the temperature to max. 40 °C.
– For high-pressure cleaners with adjust-
able water quantity:
Work with the maximum water quantity.
– Employ at least 2 people to perform the
cleaning work, assistance with trailing
the free hose length or to operate the
high-pressure cleaner.
– A safe workplace during cleaning, lifting
platforms.
Cleaning
Note: Please read and observe the safety
instructions prior to use!
DANGER
Ensure firm footing during cleaning work.
Torque due to rotating brush, hold tightly on
to the telescopic lance during work, espe-
cially when the telescopic lance is com-
pletely or far extended.
CAUTION
Mind the maximum cleaning temperature of
40 °C! There is a risk of the brush drive be-
ing damaged with higher temperatures.
In case of blocking brushes, pay regard to
the troubleshooting section.
Move the telescopic lance only lengthwise
during work, not sideways.
 Operate the high pressure cleaner as
instructed in the operating instructions.
Illustration
 Extend telescopic lance if necessary:
Open the locking lever and pull the
pipes out to the required length.
Note: Always start by extending the
front (thinner) pipes first.
 Close locking lever.
Illustration
 Open stop-cock and start cleaning.
Complete cleaning
 Close the stop valve.
 Switch off the high pressure cleaner.
 Open the stop-cock again to release the
pressure still present in the system.
8

Transport and storage

 Completely push the telescopic lance
together.
 Unscrew the distributor with the clean-
ing brushes from the telescopic lance.
 Unscrew both high-pressure hoses
from the telescopic lance.
Illustration
 Coil the high-pressure hose of the tele-
scopic lance and secure it on the lance
(by means of cable ties or hook-and-
loop tape).
 Store the cleaning brushes in a way that
no bristles are damaged or distorted.
 Store the solar cleaning kit in a frost-
protected and dry place.

Troubleshooting

High-pressure cleaner switches on/
off
 With certain appliances: Stop-cock is
not completely opened.
 With closed stop-cock: Leakage in the
system, contact service.
Cleaning brush is not rotating
CAUTION
When brush is blocking, close the stop-
cock and switch off the high-pressure
cleaner.
 Contact service.
Detergent is not getting sucked in
 Detergent intake only possible with
heated high-pressure cleaners (HDS
appliances).
Clamping of telescopic lance does
not clamp
 Clamping does not clamp.
 Readjust clamping, in order to do so,
retighten the screw at the side of the
locking lever.
Note: If necessary, new locking levers can
be re-ordered.
Lock lever
Order No.
ø 36 mm
6.373-995.0
ø 34 mm
6.373-996.0
ø 28 mm
6.373-997.0
3
-
EN

Installation declaration

We herewith declare that we have com-
piled the technical documentation for the
incomplete machine listed in the following
as per the EU directive 2006/42/EG
(+2009/127/EG) Appendix VII Part B and
that the machine meets the following re-
quirements of this directive:
Appendix I Items 1.1, 1.2, 1.3, 1.4, 1.5, 1.6
and 1.7.
This declaration shall cease to be valid if
the incomplete machine is modified without
our prior approval..
Product:
Accessories
iSolar 400
iSolar 800
Type:
6.368-454.0, 6.368-455.0
6.368-456.0, 6.368-457.0
Applied harmonized standards
With reference to:
EN 60335–2–79
Authorities can request relevant docu-
ments about the imcomplete machine from
the documentation official. The documents
are transmitted via E-Mail.
Prior to starting up or installing the incom-
plete machine you must make sure that the
machine, in which the incomplete machine
will be run or into which it will be installed,
complies with the EU machine directive
2006/42/EG (+2009/127/EG). Further infor-
mation about this is available in the EU con-
formity declaration for this machine.
The undersigned act on behalf and under
the power of attorney of the company man-
agement.
CEO
Head of Approbation
Authorised Documentation Representative
S. Reiser
Alfred Kärcher GmbH Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Phone: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2013/04/01

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Isolar 800

Table des Matières