Specifications – MonoDrive/MonoDriveXT
NEMA 3R
Model No.
(indoor/outdoor)
Voltage
Phase In
Frequency
Current (max)
Input from
Power Factor
Power Source
Power (idle)*
Power (max)
Wire Gauge Size(s)
Voltage
Phase Out
Frequency Range
Output to Motor
Current (max)
Wire Gauge Size(s)
Factory Preset
Pressure Setting
Adjustment Range
Temperature
(at 230 VAC input)
Operating
Conditions
(A)
Relative Humidity
Controller Size
(B)
NEMA 3R
(approximate)
Pump (60 Hz)
For Use With
FE Motor
Notes:
(A) Operating temperature is specified at full output power when installed as described in Location of Drive on pg. 13-14.
(B) Refer to pg. 25-26 for detailed Drive Mounting.
* Idle power is defined as input power used by the drive when the drive is not running the motor, the drive fan is off, and no
communication is active. Idle power is increased by 1 W if Wi-Fi is on.
MonoDrive
587 020 5003
208/230 VAC
Single-Phase
60/50 Hz
11A
~0.95
4 W
2.5 kW
Consult Federal, State, and Local codes
for branch circuit installations
230 VAC
Single-Phase, (3-Wire)
30-63 Hz
10.4 A
See pg. 18 for circuit breaker and wire sizing
50 psi (3.4 bar)
25-80 psi (1.7 - 5.5 bar)
-13 °F to 122 °F (-25 °C to 50 °C)
20-95%, non-condensing
9-3/4" x 16-3/4" x 5-1/4" : 20 lbs
(25 x 42.5 x 13 cm) : (9 kg)
0.5 hp (0.37 kW) pump with 214505-series motor
0.75 hp (0.55 kW) pump with 214507-series motor
1.0 hp (0.75 kW) pump with 214508-series motor
214505-series (0.5 hp, 0.37 kW) single-phase, 3-wire
214507-series (0.75 hp, 0.55 kW) single-phase, 3-wire
214508- series (1.0 hp, 0.75 kW) single-phase, 3-wire
SubDrive/MonoDrive
MonoDriveXT
587 020 5203
208/230 VAC
Single-Phase
60/50 Hz
16A
~ 0.95
5 W
4.2 kW
Consult Federal, State, and Local codes for branch
circuit installations
230 VAC
Single-Phase, (3-Wire)
30-63 Hz
13.2 A
See pg. 18 for circuit breaker and wire sizing
50 psi (3.4 bar)
25-80 psi (1.7 - 5.5 bar)
-13 °F to 122 °F (-25 °C to 50 °C)
20-95%, non-condensing
9-3/4" x 19-3/4" x 5-1/4" : 26 lbs
(25 x 50 x 13 cm) : (11.8 kg)
1.0 hp (0.75 kW) pump with 214508-series motor
1.5 hp (1.1 kW) pump with 224300-series motor
2.0 hp (1.5 kW) pump with 224301-series motor
214508-series (1.0 hp, 0.75 kW) single-phase, 3-wire
224300-series (1.5 hp, 1.1 kW) single-phase, 3-wire
224301-series (2.0 hp, 1.5 kW) single-phase, 3-wire
5