Service settings menu is displayed.
3) Select

Test Operation

press Menu/OK button. Basic screen returns and "Test
Operation" is displayed at the bottom.
4)
operation starts.
Monitor the operation of the indoor unit for a minimum
of 10 minutes. During test operation, the indoor unit
will continue to cool/heat regardless of the temperature
setpoint and room temperature.
In the case of above-mentioned procedures 3) and 4)
in reverse order, test operation can start as well.
5) Press Menu/OK button in the basic screen. Main menu is
displayed.
6) Select

Air Flow Direction

operation manual.
7)
press Menu/OK button. Basic screen returns.
8)
the basic screen.
Service settings menu is displayed.
9) Select
Test Operation
press Menu/OK button. Basic screen returns and normal
operation is conducted.
Test operation will stop automatically after 15-30
minutes. To stop the operation, press On/Off button.
10) If the decoration panel has not been installed, turn off the
power after the test operation.
English
in the service settings menu, and
in the main menu and check
in the service settings menu, and

Basic screen

1)
2)
Cool
Set to
Cool
68
F
Press and hold Cancel
button for 4 seconds or
Return
longer during backlight lit.
3)
Service Settings
1/3
Test Operation
Maintenance Contact
Field Settings
Press Menu/OK button.
Energy Saving Options
Prohibit Buttons
Min Setpoints Differential
Setting
4)
5)
Cool
Set temperature
80
Press On/Off button
°F
(within 10 seconds).
Test Operation
Press Menu/OK button.
6)
MainMenu
1/2
Air Flow Direction
Ventilation
Schedule
Press Menu/OK button.
Off Timer
Celsius / Fahrenheit
Maintenance Information
Setting
7)
Air Flow Direction
Swing
direction by using
Setting
(Up/Down)button.
Press Menu/OK button.
8)
Cool
Set temperature
80
Press and hold Cancel
°F
button for 4 seconds or
Test Operation
longer during backlight lit.
9)
Service Settings
1/3
Test Operation
Maintenance Contact
Field Settings
Press Menu/OK button.
Energy Saving Options
Prohibit Buttons
Min Setpoints Differential
Setting
Basic screen
18