2.1 VariTrans® P 43000 D2 TRMS-0001-KTA
Measuring ranges
The device is designed as a multi-range transmitter.
The ranges are selected using an insulated rotary encoder switch on
the device front. Each input range is assigned to a switch position
"Test > 22 mA".
Input
0 ... 5.0 A AC
0 ... 5.0 A AC
0 ... 5.0 A AC
0 ... 1.6 A AC
0 ... 1.6 A AC
0 ... 1.6 A AC
0 ... 1.2 A AC
0 ... 1.2 A AC
0 ... 1.2 A AC
0 ... 1.0 A AC
0 ... 1.0 A AC
0 ... 1.0 A AC
0 ... 0.8864 A AC
0 ... 0.8864 A AC
0 ... 0.8864 A AC
not used
52
Output
0 ... 20 mA
4 ... 20 mA
Test > 22 mA
0 ... 20 mA
4 ... 20 mA
Test > 22 mA
0 ... 20 mA
4 ... 20 mA
Test > 22 mA
0 ... 20 mA
4 ... 20 mA
Test > 22 mA
0 ... 20 mA
4 ... 20 mA
Test > 22 mA
Rotary switch
0 (default)
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F