Operating Instructions
Safety Switches GP...

Inspection and service

WARNING
Danger of severe injuries due to the loss of the
safety function.
If damage or wear is found, the complete switch
f
and actuator assembly must be replaced. Re-
placement of individual parts or assemblies is
not permitted.
Check the device for proper function at regular
f
intervals and after every fault. For informa-
tion about possible time intervals, refer to
EN ISO 14119:2013, section 8.2.
Inspection of the following is necessary to ensure
trouble-free long-term operation:
correct switching function
f
secure mounting of all components
f
damage, heavy contamination, dirt and wear
f
sealing of cable entry
f
loose cable connections or plug connectors.
f
Information: The year of manufacture can be seen
in the bottom, right corner of the type label.
Exclusion of liability and warranty
In case of failure to comply with the conditions for
correct use stated above, or if the safety instruc-
tions are not followed, or if any servicing is not
performed as required, liability will be excluded and
the warranty void.
Notes about
The following information applies to devices
with cable entry:
For use and applications as per the requirements
of
, a copper wire for the temperature range
60/75 °C is to be used.
The following information applies to devices
with plug connector:
For use and applications as per the requirements of
, a class 2 power supply according to UL1310
must be used. Connection cables for safety switches
installed at the place of use must be separated
from all moving and permanently installed cables
and un-insulated active elements of other parts
of the system which operate at a voltage of over
150 V. A constant clearance of 50.8 mm must be
maintained. This does not apply if the moving cables
are equipped with suitable insulation materials which
possess an identical or higher dielectric strength
compared to the other relevant parts of the system.

EC declaration of conformity

The manufacturer named below herewith declares
that the product fulfills the provisions of the direc-
tive(s) listed below and that the related standards
have been applied.
EUCHNER GmbH + Co. KG
Kohlhammerstr. 16
D-70771 Leinfelden-Echterdingen
Directives applied:
Machinery directive 2006/42/EC
f
Standards applied:
EN 60947-5-1:2004 + Cor.:2005 + A1:2009
f
EN 1088:1995+A2:2008
f
EN 14119:2013
f
The original EC declaration of conformity can also
be found at: www.euchner.de
Service
If service support is required, please contact:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
D-70771 Leinfelden-Echterdingen
Service telephone:
+49 711 7597-500
Fax:
+49 711 753316
E-mail:
support@euchner.de
Internet:
www.euchner.de
5

Technical data

Parameter
Value
Housing material
Reinforced thermoplastic
Degree of protection acc. to
IEC 60529
GP1... (cable entry)
IP67
GP2... (plug connector)
IP65
Mech. life
2 x 10
operating cycles
6
Ambient temperature
-20 ... +80 °C
Degree of contamination
3 (industrial)
(external, acc. to EN 60947-1)
Installation position
Any
Approach speed, max.
20 m/min
Extraction force
20 N
Retention force
2 N
Actuating force, max.
10 N
Actuation frequency
6700/h
Switching principle
Slow-action switching contact
Contact material
Silver alloy, gold flashed
Connection
GP1...
Cable entry M20 x 1.5
GP2...SR11
Plug connector SR11, 11-pin+PE
(not connected)
Conductor cross-section
(flexible/rigid)
GP1...
0.34 ... 1.5 mm²
Operating voltage for optional
L060 12 - 60 V
LED indicator
L110 110 V
(only GP...538H)
L220 230 V
Conditional short-circuit
100 A
current
Switching voltage, min.,
12 V
at 10 mA
Switching current, min., at 24 V 1 mA
Short circuit protection
(control circuit fuse) acc. to
4 A gG
IEC 60269-1
Conventional thermal
4 A
current I
th
Utilization category acc. to EN 60947-5-1
GP1...
AC-15 4 A 230 V
DC-13 4 A 24 V
GP2...SR11
AC-15 4 A 50 V
DC-13 4 A 24 V
Rated insulation voltage
GP1...
U
= 250 V
i
GP2...SR11
U
= 50 V
i
Rated impulse withstand voltage
GP1...
U
= 2.5 kV
imp
GP2...SR11
U
=1.5 kV
imp
Reliability values acc. to EN ISO 13849-1
B
3 x 10
6
10d