Practical Notes
Operation mode
With the potentiometer on the front plate the operartion mode can be
adjustet. The adjustment must be required before energizied. Adjustment
during energization is not allowed.
Only an automatic start at safety function two-hand control (3) is possible.
Start
Fkt. 1
Fkt. 2
1
MANUAL
MANUAL
2
MANUAL
AUTO
3
AUTO
HAND
4
AUTO
AUTO
MANUAL with common
5
button
Line fault detection e.g. monitoring of ON-button
If the On-button pressed more than 3 s the adequate output contacts of the
safety function can't be switch. The output contacts can be energized when
the On-button pressed again (0.1 s < t
A line fault is detected if the On-button more than 10 s is actuated. The
output contacts of the adeauate safety function can only be energized with
a reset or re-start with on an off switching of power supply.
ATTENTION - AUTOMATIC START!
According to IEC/EN 60 204-1 part 9.2.5.4.2 and 10.8.3 it is
not allowed to restart automatically after emergency stop.
Therefore the machine control has to disable the automatic
start after emergency stop.
Reset and external failures:
The reset input is used to reset external failures (application failures or
removable external failures as e.g. a line fault on reset button). If the reset
signal is connected to the input for more than 3 sec the unit unit makes a
reset. A new reset is only possible when the reset signal had been switched
off temporarily.
If an external failure occurs because both input channels of a safety function
did not switch on or off within the simultanious time, a reset is only possible
if both channels are switched to off state after removing failure cause.
If an external failure occurs in only one safety function, only this function
will be disconnected. The second safety function still continuous to work.

Function setting

The variants with selectable safety functions have 2 potentiometers Fkt.1
and Fkt.2 to select the required function. The following functions are possible:
Fct. 1 / Fct. 2
Safety function
1
2
Safety gate
3
Two-hand control
4
Safety mat / Safety edge
5
Exclusive or contacts
6
7
Safety gate
8
Light curtain
< 3 s).
ON
E-Stop
cross fault detection
E-Stop
without
cross fault detection
Operating Potentiometer
Poti "Start"
Poti "Fkt.1"
Poti "Fkt.2"
Indicators
green LED ON:
red LED ERR:
green LED K1/K2:
green LED K3/K4:
Fault Indication by Flashing Code
Potentiometer or
adjustment failure
line fault across
start button
Cross fault or
wiring fault
simultaneity
error
6
Adjustment of operating mode
Manual- or auto start for Fkt.1 and Fkt. 2.
Adjustment of safety function 1
Adjustment of safety function 2
on, when supply connected
on, at internal error
flashes at external error
on, when relay K1 and K2 energized
(safety function 1)
flashes at external errors of
safety function 1
on, when relay K3 and K4 energized
(safety function 2)
flashes at external errors of
safety function 2
03/2021 DE-EN-FR