Insert the cable into the charging station and fasten it with a cable gland. (The cable can be
inserted either through the back or through the existing cable gland entry at the bottom of
the station. If you do not use the cable gland entry, please make sure it is properly sealed.)
Connect the cores to the relevant components as indicated.
Connect the phase wires* to the indicated L1 / L2 / L3 connecting terminals.
Connect the Null wire to the indicated Null terminal.
Connect the shield/ground wire to the indicated Ground terminal.
When fastening the cores, use the correct screwdriver and tighten to 3.5Nm to 5Nm. Do not
forget to attach the loose ground wire from the charging station to the cover.