4. Installation
4.1
General
• Mount vertically on a non-flammable surface, with the power
terminals facing downwards. Observe a minimum clearance of
10 cm under and above the product for optimal cooling.
• Mount close to the battery, but never directly above the battery
(in order to prevent damage due to gassing of the battery).
4.2
Connection setup for DC-DC converter mode
1. Disconnect the remote on/off (remove wire bridge).
2. Connect the input supply cables.
3. Open the VictronConnect App to setup the product.
(always adjust the output voltage before connecting in
parallel or connecting a battery)
4. Connect the load. The converter is now ready for use.
5. Reconnect the remote on/off to activate the product.
Figure 1: Typical connection setup as DC-DC converter
7