16 electrolux
Energy efficiency class
Energy consumption (8 kg of cotton, pre-
drained at 1000 rpm)
Average annual energy consumption
Use
Permissible ambient temperature
The consumption values have been established under standard conditions. They may de-
Katoen Kast droog (COTTON CUP-
2) 3)
BOARD)
Katoen Strijkdroog (COTTON IRON)
Synthetisch Kast droog (SYNTHETICS CUP-
2)
BOARD)
1) Different loading volume data may be needed in some countries as a result of different measuring methods.
2) in accordance with EN 61121

MACHINE SETTINGS

Setting
Zoemer (BUZZER ) perma-
nent off
Water hardness
Water contains, a variable
quantity of limestone and min-
eral salts of which quantities
vary according to geographi-
cal locations thus varying its
conductivity values.
Relevant variations of the con-
ductivity of the water com-
pared to those prefixed by the
factory could slightly influence
the residual humidity of the
laundry at the end of the cy-
cle. Your dryer allows you to
regulate the sensitivity of the
drying sensor based on con-
ductivity values of the water.

HINTS FOR TEST INSTITUTES

Parameters possible to checked by the
Test Institutes:
2)
Consumption values
viate when the machine is operated in domestic circumstances.
Programme
1. Turn the programme selector to any programme.
2. Press simultaneously the Zoemer and Droogtegraad but-
tons and hold down for approx. 5 seconds.
3. The buzzer is by default always off. You can use Zoemer but-
ton to activate or deactivate sound but machine does not mem-
orize your selection.
1. Turn the programme selector to any programme.
2. Press simultaneously the Droogtegraad and START/PAUZE
buttons and hold down for approx. 5 seconds. The current set-
ting is on the display:
3. Press the START/PAUZE START PAUZE button sequentially
until you set desired level.
4. To memorize setting press simultaneously the the Droogte-
graad and START/PAUZE buttons or turn knob to O off po-
sition
B
4.48 kWh
282 kWh
Domestic
+ 5°C to + 35°C
Energy consumption in kWh / average
4.48 / 135 (8 kg load pre-drained at 1000
rpm)
4,30 (8 kg load pre-drained at 1400 rpm)
2)
3.8 / 108 (8 kg load pre-drained at 1000 rpm)
1.30 / 45 (3 kg load pre-drained at 1200 rpm)
Implementation
low conductivity <300 micro S/cm
medium conductivity 300-600 micro S/cm
high conductivity >600 micro S/cm
• Energy consumption (corrected with final
humidity) during the cupboard dry cotton
cycle with nominal load.
drying time in min.