Tool Identification; Decals - Greenlee HDE RT-10 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Tool Identification

1. Clamps
2. Indicator LEDs (Red)
3. Power Button
4. Battery Door &
Thumbscrews
5. Buzzer
6. Magnets

Decals

A. Face Overlay
B. Instructions and
Warnings
2.13"
B
An improperly tested rope increases the risk of electric shock when
using near high voltage lines. Touching the clamps may cause
electric shock. Always turn off unit before touching the clamps.
Test rope as close to the time of use as possible.
1. Confirm proper operation. See instructions.
2. Open clamps and place rope across clamps.
3. Close clamps over the rope.
4. Turn unit ON. Grip the handle with one hand to keep the
tester steady.
5. With the other hand, pull the rope through the clamps. Keep a
steady pace. The tester works in both directions. If rope is
conductive the red LEDs will light, and the buzzer will sound.
Pulling the rope too quickly increases the risk of not detecting
conductive sections of the rope.
6. Turn the tester OFF.
7. After testing the rope, reconfirm proper operation
of the rope tester.
9V Lithium or Alkaline only
Greenlee Tools, Inc.
www.Greenlee.com
4
Top
5
A
3
Bottom
52092995 REV 0
© 2020 Greenlee Tools, Inc.
RT-10 Rope Tester
1
2
6
4
B
52093863 REV 0

Publicité

Table des Matières
loading

Table des Matières