Télécharger Imprimer la page

Digi Sport Instruments DT2500P Guide Rapide page 14

Masquer les pouces Voir aussi pour DT2500P:

Publicité

Les langues disponibles

Les langues disponibles

Fig. 30
DigiLink UPLOAD
PROGRAM MANUAL
A) Digilink program & driver
installation
B) Program Functions:
1) Download memorized records
2) Real time Download
3) Saving records
4) Delete record
5) Export file
6) Print Setup/Print
C) Program uninstallation
A) Digilink program & driver
installation:
1) Insert the CD disk labelled
DigiLink program to the CD Rom
drive.
2) Follow the on-screen instructions
to install the Digilink program and
the
AU9720 driver to the PC.
3) Restart
4) After restart, plug in the USB
upload cable with the stopwatch
connected.
5) Take note from the display the
COM port no. through which the
driver is connected to the PC.
[Note: In case the Com port no.
assigned is not within 1 to 4, go to
the control panel to adjust. You can
view the port number by first
clicking the ' Control Panel ' and
choose ' System '. Then, click the '
Hardware ' in the System
Properties and choose ' Device
Manager '. The port number can be
found in the ' USB to Serial Bridge
Controller ' inside the Ports
(COM&LPT). The port number can
be changed by right clicking the '
USB to Serial Bridge Controller '
and choose ' Properties '. The
Communication Port properties
window will pop up, choose ' Port
Settings ' and click ' Advanced '.
Then, you can choose another port
(COM1-COM4) in the Com port
number.]
6) Double click the 'DigiLink' icon
on the desktop.
7) From the program pull down
menu, click 'SETTING' and select
'PORT'.
A list of COM port no.(COM1-
COM4) will be displayed. Match
this COM
port no. to the one noted in A5
and click 'OK' to accept. If an
incorrect port number is selected,
Fig. 31
nothing will be transferred to the
computer.
8) Continue function. This
function located in the 'SETTING'
pull down menu.
Click 'Continue' for either enable
or disable. This function affects
the way of saving race record into
file.
A 'tick' symbol appearing next to
'Continue' means it is enabled. All
race records will be saved in one
file, each time executing
'Download' function. DigiLink
program will not prompt the user
to save file unless start download
new record or exit program. If tick
symbol is not appearing
(disabled). DigiLink will prompt
the user to save each race record
into a file before next race record
start transferring to the computer.
For example, if user transfers
3 race records to the computer,
DigiLink program will prompt the
user to save the first and second
record. The user has to save the
last record by clicking
'Save' or 'Save as' in the pull
down menu, or the computer will
prompt to save the last record
until the user start transfer new
race record or exit the DigiLink
program.
B) Program Functions:
1) Download memorized records
from stopwatch:
At the main screen of the DigiLink
program click 'FILE' from the pull
down menu and then select
'Download'. Press stopwatch start
button to transfer all records stored
in the stopwatch. When all records
have been transferred to the
computer, the stopwatch will show
'UPLOAD END' on the display for
2 second. Click "Disconnect" then
'Back' button to return to main
screen.
2) Real time Download:
User can transfer data to computer
simultaneously when operate the
stopwatch in Chrono mode. Please
note that the record number in
DigiLink program always start from
MCH-000 every time in this mode.
Therefore the race record number
can be different in DigiLink
program and stopwatch. DigiLink
program allows user to record
maximum 10000 laps from
stopwatch. Any laps exceeding
10000 will not be saved in the
record.
3) Saving files:
When saving files to computer.
Default file name format will be
suggested by DigiLink e.g. file
name MCH-001-010925, will be
suggested for record number
MCH-001 and recorded on 25th
September 2001. User can change
the file name if needed.
4) Delete records:
To delete record, first select
unwanted race record by clicking
the down arrow button next to it in
'Record Cell'. Click 'DELETE
RECORD' then click 'OK' to accept
the delete record dialog.
5) Export files:
The DigiLink program allows user
to export files in the text format.
Select 'EXPORT' then click 'TEXT'
from the 'FILE' pull down menu.
'SAVE AS WINDOWS' will be
displayed; user can save the file to
another file name and path in your
computer. Because the exported
file is in text format, it can be
opened by Windows note pad,
Microsoft WORD or EXCEL
programs for further processing.
6) Print Setup/Print:
Select the printer and print
orientation in 'PRINT SETUP' of the
'FILE' pull down menu. Click
'PRINT' in the 'File' pull down menu
will print the current race file
immediately.
C) Program uninstallation:
To remove DigiLink program, go to
CONTROL PANEL, double click
ADD and REMOVE, select 'DigiLink
version 1.1' then click REMOVE.
This will completely remove the
DigiLink program from the
computer.
For uninstalling the AU9720 driver,
go to CONTROL PANEL, double
click ADD and REMOVE, select
'USB CDC Device Driver', then
click REMOVE. The AU9720 driver
will then be removed from the
computer.
THE WARRANTY DOES
NOT COVER THE
BATTERY.

Publicité

loading

Produits Connexes pour Digi Sport Instruments DT2500P