NOZZLES:
Nozzles should be cleaned or replaced at least once per heating
season. Contaminated fuel could make this necessary
.
immediately
To clean dirt from nozzle, blow compressed air through nozzle
front. It may be necessary to soak nozzle in clean 1-K kerosene
to help loosen any particles.
NOTE: Use of diesel may require additional maintenance. Using
this heater without proper maintenance or with contaminated or
old fuel may lead to improper combustion and possible soot
production. BE SURE FUEL USED  IS APPROVED (see
OPERATION on page 6).
Burner Head
Nozzle
Nozzle Face
Air Line Fitting
Figure 15: Nozzle Replacement
© 2012, Pinnacle Products International, Inc.
Maintenance (Continued)
Burner Head
Screw

Spark Plug

Ignitor Wire
Fuel Line Hose
Air Line Hose
Fuel Line Fitting
SPARK PLUG:
Clean and re-gap every 600 hours of operation, or replace as
needed.After removing the Spark Plug, clean the terminals with a
wire brush. Re-gap the terminals to 0.140" (3.5mm).
Burner Head
Figure 16: Spark Plug Replacement
PHOTOCELL:
The Photocell should be cleaned at least once per heating
season or more depending on conditions.
Use a cotton swap dipped in water or alcohol to clean the lens of
the Photocell. Note the proper Photocell position as noted in
Figure 17 and Figure 18.
Photocell
Installing Photocell:
Figure 17: Photocell Positioning
10
Kerosene User's Manual
NEVER LEAVE HEATER
UNATTENDED WHILE BURN-
ING OR WHILE CONNECTED
TO A POWER SOURCE
Spark Plug
Gap
Photocell
Lens
1) Incorrect
2) Correct
Ignitor Wire

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Hs-70t-kfaHs-125t-kfaHs-175t-kfaHs-215t-kfa

Table des Matières