SMOKE PROBE ALARM
This indicates a failure of the smoke probe.
A message is displayed on the screen, the appliance triggers an alarm and proceeds to a shutdown phase.
Solution: If the issue continues, we recommend you call a qualified professional to analyse and remedy the issue.
HOT SMOKE ALARM (excessive smoke temperature):
This indicates that the temperature of the smoke from the fuel is too high due to:
Poor maintenance of the appliance. (accumulation of ash in the appliance's internal ducts)
A measurement failure by the smoke probe.
A message is displayed on the screen, the appliance triggers an alarm and proceeds to a shutdown phase.
Solution:
First occurrence: be sure to perform proper periodic maintenance.
Second occurrence: contact a qualified professional to adjust the combustion settings or the smoke
probe.
FAULTY FAN ALARM (insufficient extraction of smoke):
This indicates a failure of the smoke extractor.
The message is displayed on the screen, the appliance triggers an alarm and proceeds to a shutdown phase.
Solution: Contact a qualified professional.
NO IGNITION ALARM (ignition failure):
This indicates that the ignition phase has not reached a sufficient temperature for the appliance to be considered turned
on:
A message is displayed on the screen, the appliance triggers an alarm and proceeds to a shutdown phase.
Solution:
Check that the hopper is filled with pellets, pre-load the auger if this has not been done.
Check that the burner is clean (see section 3.3).
Verify that the burner is correctly positioned on its support.
Check that the smoke boxes and smoke paths are properly cleaned (see sections 3.4 and 3.5).
OUT OF PELLETS ALARM:
This indicates that the fuel tank (hopper) is empty.
Solution:
Fill the hopper with pellets, pre-load the auger.
Remove all fuel from the burner.
Pre-load the auger (see section 2.9.6)
WARNING: If the flame is extinguished during combustion, correct and increase the calibration setting from MENU 08 -