3.3

FRAMING

Prepare rough in framing following the recommended dimensions in Figure 1. For the corner rough in framing,
follow the recommended dimension in Figure 2.
Select a location that is not prone to moisture and is located at least 36" (914mm) away from combustible
materials such as curtain drapes, furniture, bedding, paper etc.
Fig. 1
A
BEF33H
A
10"
(254mm)
B
33 1/2"
(851mm)
C
28 1/4"
(718mm)
J
48"
(1219mm)
K
34"
(864mm)
L
34"
(864mm)
A.
Once the rough opening has been prepared, and the power has been routed to the right side of the
recess, the appliance may be installed.
B.
The electrical connection must be made prior to sliding the appliance into place. (See "HARD
WIRING INSTALLATION" section). Slide the appliance into the wall.
C.
To secure the appliance to the wall, remove the glass door (See "GLASS DOOR REMOVAL AND
INSTALLATION" section) and log / grate / ember bed (See "LOG, GRATE AND EMBER BED
ASSEMBLY REMOVAL" section).
D.
Level the appliance and use the 4 screws provided to secure the appliance to the wall studs, refer to
Figure 3..
E.
Install the brick panels (See "BRICK PANEL INSTALLATION AND REMOVAL" section), log /grate
and ember bed assembly and the glass door to the appliance.
NOTE: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact
with the appliance body, it is recommended that the walls of the appliance enclosure be "fi nished"
(ie. drywall/sheetrock), as you would fi nish any other outside wall of a home. This will ensure that
clearance to combustibles is maintained within the cavity.
B
BEF40H
14 1/2"
(368mm)
39 1/2"
(1003mm)
31 1/4"
(794mm)
62"
(1575mm)
44"
(1118mm)
44"
(1118mm)
Fig. 2