Congratulations!
®
Your TwinTemp
unit is designed for dependable cooling and heating. These units are sim ple to op er ate and provide max-
i mum effi ciency and quietness.
Table of Contents
Before Operating Your Unit .....................................................................................................................................................2
To Start Unit .............................................................................................................................................................................4
Control Panel for models YS09, YS13, YM18, YL24, ES12, ES16, EM18, EM24, EL25 and EL36 ......................................4
Function Control .....................................................................................................................................................................4
Temperature Control .................................................................................................................................................................4
®
MoneySaver
Feature ...............................................................................................................................................................4
To Remove Filter .......................................................................................................................................................................5
Fresh Air and Exhaust Control ................................................................................................................................................5
Control Panel For Models YQ07, EQ08 ..................................................................................................................................6
Temperature Control ...............................................................................................................................................................6
Function Control .......................................................................................................................................................................6
To Remove Filter .......................................................................................................................................................................6
Heat Pumps Are Different In The Way They Operate ...........................................................................................................7
Troubleshooting Tips ................................................................................................................................................................7
Warranty ....................................................................................................................................................................................8
WARNING: Before operating your unit
Make sure the wiring is adequate for your unit.
If you have fuses, they should be of the time delay type.
Before you install or re lo cate this unit, be sure that the
amperage rating of the circuit breaker or time delay fuse
does not exceed the amp rating listed in Figure 1.
DO NOT use an extension cord.
The cord provided will carry the proper amount of electrical
power to the unit; an ex ten sion cord will not.
2
920-003-10 (4-05)
Make sure that the receptacle is compatible with
the air conditioner cord plug provided.
This insures proper grounding. If you have a two-prong
receptacle you will need to have the circuit replaced by
a certifi ed electrician with a grounded circuit that meets
all national and local codes and ordinances. Under no
circumstances should you remove the ground prong from
the plug. You must use the three-prong plug fur nished with
the air con di tion er.