Télécharger Imprimer la page

Velux KLA S105 Mode D'emploi page 4

Masquer les pouces Voir aussi pour KLA S105:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
2
Contents of rain and wind sensor set KLA S105
1
Rain and wind sensor KLA 105
2
Power supply unit 3UC A02
3
Interface KLF 100
6 VELUX
®
1
3
The rain and wind sensor consists of a rain sensor surface and a wind
wheel. It is used for automatic control of comfort ventilation. The sensor
is equipped with a potential-free change-over contact with a contact
rating of 20 V / 1.8 A. In the event of rain and/or wind, the change-over
contact switches (from N/C contact to N/O contact) and the modular
skylight closes.
Wind trigger threshold, actuation delay, drop out delay and actuation in
the event of power failure are set on a 6 pole DIP switch in the sensor.
Function
Wind triggered actuation
The potential-free contact switches when the wind sensor is actuated.
The red light-emitting diode in the sensor is lit. The wind speed at which
the wind sensor is actuated is settable.
Note: Depending on your settings, the wind sensor will be reset 10 or
20 minutes after the last sensor actuation.
Rain triggered actuation
The potential-free contact switches when the rain sensor is actuated.
The red light-emitting diode in the sensor is lit.
Note: Depending on your settings, the rain sensor will be reset 10 or
20 minutes after the last sensor actuation.
Technical data
Voltage from power supply unit 3UC A02:
Circuit output:
Contact rating:
Dimensions:
80 x 160 x 55 mm (WxHxD, without wind wheel)
Weight:
Protection degree:
Setting of wind trigger threshold:
Setting of wind or rain drop out delay:
Setting of wind actuation delay:
Setting of monitoring:
20 V DC
1 potential-free change-over contact
20 V / 1.8 A
Approx 0.7 kg
IP65
Approx 3 to 14 m/s (±20%)
10 min/20 min
2 sec/5 sec
OFF/ON
VELUX
®
7

Publicité

loading