AM-1 1070 SERIES PROPORTIONAL THERMOSTATIC MIXING VALVE

APPLICATION INFORMATION

For domestic hot water applications the mix temperature
upper limit must not exceed a temperature of 120° F (49° C) to
prevent scalding.
ASSE 1070 Applications-Point of
Use:
Individual showers, baths or a combination of: automatic
faucets, nursing homes, public facilities and wherever ASSE
1070 valves are required.
2-1/4
(57)
H
B
Fig. 1. Dimension Diagram.
INSTALLATION
NOTE TO INSTALLER: This product should be installed by a
qualified individual, in accordance with local codes and
ordinances. It is the responsibility of the installer to properly

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the
TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory).
2. Honeywell Customer Care
1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386
3. http://customer.honeywell.com or http://customer.honeywell.ca
In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Toronto, Ontario M1V 4Z9.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France,
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
62-3114EF—01
A
Ø 1-51/64
(46)
C
MIX
C
M23938
select, install and adjust these devices as specified in these
instructions. For installations, which require compliance with
Building/Mechanical/Plumbing Codes, the appropriate AM
Series Valve must be chosen and installed and the discharge
temperature set and locked according to these instructions.
These models shall be used to supply water to tubs, showers,
bathing facilities and other outlets. These valves should be
installed where they will be accessible for cleaning, servicing
or adjustment.
NOTE: Pressure difference between Hot and Cold ports
should not exceed 10 psi (68.9 kPa).
Installation of Union Sweat, CPVC
and PEX Connections
— Union sweat connections, if used, should be soldered
prior to assembly to the valve, or without the sealing
gasket or optional check valve present. After the joint
has cooled, the sealing gasket and/or check valves
may be installed.
— CPVC fittings are limited to a system maximum tem-
perature of 180° F (82° C) and 100 psi (689 kPa).
— Pex fitting and crimp ring (provided by Installer) are
deigned to meet ASTM F1807 requirements.
— Pex tubing used with PEX fittings must meet ASTM
F876 requirements.
2