Periodic Checks; Problems, Causes And Solutions - LF MATIC AUTOTROL 460TC Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Water softener MATIC with AUTOTROL chronometric head 460TC
 PERIODIC CHECKS
AFTER THE FIRST 6-12 MONTHS, and then EVERY 6-12 MONTHS:
Clean the salt container following the procedure hereunder:
• Remove the remaining salt from the bottom;
• Clean all the walls of the container from muddy, oozy or dry salt deposits;
• Rinse several times with running water using a disinfectant and a sponge;
• Rinse again, add the same quantity of water and then add the salt.
Periodically clean the washable cartridge of the pre-filter by removing all impurities from the bottom and from
the surface of the cartridge. It is sufficient to use running water.
_________________________________________________________________________________________
TROUBLE SHOOTING

Problems, causes and solutions

PROBLEMS
Regeneration starts at a wrong time
The programmer stops during the
regeneration cycle
The programmer does not regenerate
automatically or when the start up
button is pushed
The programmer does not regenerate
automatically but only by pushing the
start up button
14
CAUSES
Timer set up incorrectly
Burnt out engine
Power supply failure
Incorrect voltage or frequency
The camshaft is blocked
Excessive supply pressure
Power supply disconnected
Damaged or burnt out engine
Burnt out feeder
Damaged or burnt out timer
Too many days between scheduled
regenerations
Burnt motor
Internal gear broken
SOLUTIONS
Set up the timer
Replace
Check connection
Check the right voltage or frequency
Remove damaging bodies from the
valve or from the camshaft
Install a pressure regulator
Connect
Replace engine
Replace feeder
Replace timer
Reduce amount of days between
regenerations
Replace motor
Replace gear

Publicité

Table des Matières
loading

Table des Matières