The pressure sensor ⁄ differential pressure sensor PREMASGARD
pressure measurement in gaseous and liquid media. It converts the measurand into
standard signals of 0-10 V or 4...20 mA. Process connection is 2 x G ⅛ " - 27 NPT internal
thread. SHD -692 differential pressure transmitters are used in piping and hydraulic
systems, in mechanical and plant engineering as well as in building automation.
Not applicable for ammonia and Freon!

TECHNICAL DATA

Power supply:
Measuring ranges:
Output signal:
Permissible working resistance: R
(at nominal voltage)
Electrical connection:
Pressure connection:
Type of pressure:
Measuring principle:
Medium:
Temperature of medium:
Mounting:
Enclosure:
Connecting head:
Medium contacting parts:
Response time:
Class:
Total error:
Overload range:
System pressure:
Bursting pressure:
Insulating resistance:
Protection class:
Protection type:
Standards:
Optional:
PREMASGARD
®
SHD 692 – Differential pressure transmitters, Deluxe
Type ⁄ WG02
SHD 692 - U
S H D 6 9 2 - U - 9 0 0
S H D 6 9 2 - U - 9 0 7
S H D 6 9 2 - U - 912
S H D 6 9 2 - U - 916
S H D 6 9 2 - U - 918
SHD 692 - I
S H D 6 9 2 - I - 9 0 0
S H D 6 9 2 - I - 9 0 7
S H D 6 9 2 - I - 912
S H D 6 9 2 - I - 916
S H D 6 9 2 - I - 918
Optional:
SHD 692
24 V AC (+15 % / –10 %), 18 - 33 V DC for U-variant
24 V DC (± 20 %) for I-variant
see table
0 -10 V (3-wire connection) or
4...20 mA (2-wire connection)
> 10 kΩ for U-variant
L
R
< 600 Ω for I-variant
L
0.25 - 1.5 mm², DIN EN 175301- 803 - A
screw pipe connection for 6 mm pipe
(G ⅛ " - 27 NPT internal thread)
differential pressure
ceramic measuring cell
liquid or gaseous
–15...+80 °C
installation arbitrary
stainless steel V2A (1.4305)
angle plug connector DIN EN 175301- 803 - A
INOX 1.4305, ceramics, sealing material EPDM
< 5 ms
0.5 %
< 1.3 %
see table
max. 25 bar (P1 + P2)
1.5 x system pressure
≥ 100 MOhm, at +20 °C (500 V DC)
III (according to EN 60 730)
IP 65 (according to EN 60 529) with receptacle mounted
CE conformity, electromagnetic compatibility
according to EN 61 326, EMC directive 2014 ⁄ 30 ⁄ EU
Display module, additional height: approx. 50 mm,
for displaying the differential pressure
Measuring Range
0...0.1 bar
0...0.5 bar
0...1 bar
0...2.5 bar
0...4 bar
0...0.1 bar
0...0.5 bar
0...1 bar
0...2.5 bar
0...4 bar
with display module
®
SHD-692 is used for
2
Output pressure 0-10V
3
GND
1
Supply voltage
UB+ 24V AC / 18-33V DC
2
Output pressure 4...20mA
3
Free
1
Supply voltage
UB+ 24V DC
(Max. One-Side
Output
Overload)
(0.6 bar )
0 -10 V
(3 bar )
0 -10 V
(5 bar )
0 -10 V
(12 bar )
0 -10 V
(12 bar )
0 -10 V
(0.6 bar )
4...20 mA
(3 bar )
4...20 mA
(5 bar )
4...20 mA
(12 bar )
4...20 mA
(12 bar )
4...20 mA
Connecting diagram
OUT
2
3
1
+
IN
2
Output pressure 0-10V
3
GND
1
Supply voltage
UB+ 24V AC / 18-33V DC
Connecting diagram
OUT
2
3
1
+
IN
2
Output pressure 4...20mA
3
Free
1
Supply voltage
UB+ 24V DC
Display
Item No.
U - variant
1 3 0 1 - 4 1 2 1 - 0 5 0 0 - 0 0 0
1 3 0 1 - 4 1 2 1 - 0 5 1 0 - 0 0 0
1 3 0 1 - 4 1 2 1 - 0 5 2 0 - 0 0 0
1 3 0 1 - 4 1 2 1 - 0 5 3 0 - 0 0 0
1 3 0 1 - 4 1 2 1 - 0 5 4 0 - 0 0 0
I - variant
1 3 0 1 - 4 1 2 2 - 0 5 0 0 - 0 0 0
1 3 0 1 - 4 1 2 2 - 0 5 1 0 - 0 0 0
1 3 0 1 - 4 1 2 2 - 0 5 2 0 - 0 0 0
1 3 0 1 - 4 1 2 2 - 0 5 3 0 - 0 0 0
1 3 0 1 - 4 1 2 2 - 0 5 4 0 - 0 0 0
on request
Rev. 2018 - V12 GB
SHD 692 - U
GND
OUT
2
1
IN
SHD 692 - I
OUT
2
1
IN

Publicité

Table des Matières
loading

Table des Matières