Function and features

• The flow monitor detects the flow rate of water,
• shows the current flow rate on its display,
(max. value displayed: final value of measuring range + 20%)
• and generates 2 output signals according to the set output
configuration.
Analog output
(only output 2)
switching function
(output 1 and output 2;
function can be selected for
each output separately)
output polarity (applies to both
switching outputs)
Application: water.
(please see the maintenance details on page 29)
• For seamless precision steel to DIN 2391/1 and T-pieces to
DIN 2353.
• Adjustable to T-pieces with nominal diameter of 15 mm, 19 mm or
24 mm.
Nominal diameter
15 mm
19 mm
24 mm

Measuring range

litre / min.
gallons / min.
1)
litre / hour
gallons / hour
cubic metre / hour
for nominal
diameter
Output 1
hysteresis function / N.O. (Hno)
hysteresis function / N.C. (Hnc)
window function / N.O. (Fno)
window function / N.C. (Fnc)
p-switching (PnP)
n-switching (nPn)
T-piece
QL 18-18-18
QL 22-18-22
QL 28-18-28
0 ... 10
0 ... 2.64
0 ... 5.28
0 ... 600
0 ... 1 200
0 ... 158
0 ... 0.60
0 ... 1.20
15
Output 2
4 ... 20 mA (I)
0 ... 10 V (U)
pipe
18 x 1.5
22 x 1.5
28 x 2
0 ... 20
0 ... 10.6
0 ... 2 400
0 ... 317
0 ... 636
0 ... 2.40
19
0 ... 40
24
23

Publicité