Attention: DO NOT vent under any porch, deck, awning, or in any semi enclosed or roofed area. Doing so
may result in unpredictable airflow at the vent cap under certain conditions and can affect the performance
of your stove, as well as, other unforeseeable issues.
INSTALLATION OPTIONS
Read this entire manual before you install and use your pellet stove. Failure to follow instructions may result
in property damage, bodily injury, or even death! (See specific installation details for clearances and other
installation requirements)
A Freestanding Unit—supported by pedestal/legs and placed on a non-combustible floor surface in compliance
with clearance requirements for a freestanding stove installation.
An Alcove Unit—supported by pedestal/legs and placed on a non-combustible floor surface in compliance
with clearance requirements for an alcove installation.
Your pellet stove may be installed to code in either a conventional or mobile home (see SPECIAL MOBILE HOME
REQUIREMENTS). The installation must comply with the Manufactured Home and Safety Standard (HUD), CFR3280,
Part 24.
It is recommended that only a authorized technician install your pellet stove, preferably an NFI certified specialist.
DO NOT CONNECT THIS UNIT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
The use of other components other than stated herein could cause bodily harm, heater damage, and void your
warranty.
IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by the
malfunction of a stove due to improper venting or installation. Call (800) 750-2723 and/or consult a
professional installer if you have any questions.
CLEARANCES
Your pellet stove has been tested and listed for installation in residential, mobile home, and alcove applications
in accordance with the clearances given. For safety reasons, please adhere to the installation clearances and
restrictions. Any reduction in clearance to combustibles may only be done by means approved by a regulatory
authority.
INSTALL ALL VENTS AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER
6"
When your Pellet Stove Room Heater is being installed on a combustible floor it is mandatory that a 1/2" (13mm)
thick non-combustible hearth pad be installed under the heater. The non-combustible hearth pad must extend
at least 6" beyond the fuel loading and ash removal openings and at least the depth of the heater plus 6 inches
(152mm) out in front of the heater. The floor protector must extend 2" (51mm) beyond each side of the exhaust
vent. This applies to both freestanding heaters and insert heaters.
BACK WALL
6"
Figure 6
FLOOR PROTECTION
USA 6"
CANADA 18"
4
Installation
2"
BACK WALL
USA 6"
CANADA 8"
FLOOR PROTECTION
USA 6"
CANADA 18"
2"
BACK WALL
Alcove Dimensions
6"
USA 6"
CANADA 8"
40"
USA 6"
CANADA 18"
Alcove Dimensions
2"
FLOOR
PROTECTION
USA 6"
CANADA 8"
USA 6"
CANADA 18"
2"
2"
FLOOR
PROTECTION
36"
USA 6"
35"
CANADA 8"
USA 6"
FLOOR PROTECTION
CANADA 8"
USA 6"
CANADA 18"
Figure 5
Figure 5
USA 6"
CANADA 8"
Alcove Dimensions
2"
FLOOR
PROTECTION
USA 6"
CANADA 18"
F