DISPLAY MESSAGES

Error
code
Text on display
A002 Main phase
missing
A003 Main phase
order
A004 Pump motor
overcurrent
A005 Rotation motor
overcurrent
A007 Mixer motor
overcurrent
A011 Board over
temperature
A015 Door is open
A017 Arm stall
A019 Fuse MF3
overload
A020 Fuse MF4
overload
A023 Pump motor
phase missing
A024 Rotation motor
phase missing
A025 Mixer motor
phase missing
A026 Pump motor off
current failure
A027 Misc sensor off
current failure
B028 Heater
undercurrent
A029 Heater
overcurrent
B030 Water
temperature
sensor failure
A031 Water over
temperature
A040 Arm not in start
position
12
GP 24
Action
Check supply cable, wall
outlet and fuses.
Switch two phases in supply
plug.
Check that the pump wheel
isn't stuck. Contact your
Sales Rep.
Check that the drive roll ro-
tates smoothly. Contact your
Sales Rep.
Check that the mixer axle
runs smoothly.
Check ventilation, tem-
perature and dust around
electric box. Let the machine
cool down and try again.
Close the door. If door is
closed, check door sensor.
Check that dynamic arm
runs smoothly. Contact your
Sales Rep.
Check door sensor and
cable.
Check air blow solenoid
valve and cable.
Check that cable to pump
motor is not damaged.
Check that cable to rotation
motor is not damaged.
Check that cable to mixer
motor is not damaged.
Call your Sales Rep.
Call your Sales Rep.
Check that cable to heater is
not damaged.
Check that cable to heater is
not damaged.
Check that tempsensor
cable to heater is not dam-
aged.
Check that cable to heater is
not damaged.
Check that dynamic arm is
not stuck then run self test.
Error
code
Text on display
Action
C041 Cannot read
Restart the machine.
NVM, restart
machine
A045 Cylinder 1
Check end position
not retracted
sensor 1-.
A046 Cylinder 1
Check end position
not extended
sensor 1+.
A047 Cylinder 2
Check end position
not retracted
sensor 2-.
A048 Cylinder 2
Check end position
not extended
sensor 2+.
A049 Cylinder 3
Check end position
not retracted
sensor 3-.
A050 Cylinder 3
Check end position
not extended
sensor 3+.
A051 Cylinder 4
Check end position
not retracted
sensor 4-.
A052 Cylinder 4
Check end position
not extended
sensor 4+.
A053 Cylinder 5
Check end position
not retracted
sensor 5-.
A054 Cylinder 5
Check end position
not extended
sensor 5+.
A055 Cylinder 6
Check end position
not retracted
sensor 6-.
A056 Cylinder 6
Check end position
not extended
sensor 6+.
A057 Emergency
Reset emergency stop
stop activated
and restart machine.
A060 Problem side
Check that the side support
support
can move freely i.e no wheel
inside machine.
C061 Air pressure
Check that compressed
low
air is connected.
A062 Trolley out of
Replace the trolley
position
in start position.
C063 Terminal box
Check that the cable to the
communication
terminal box is not damaged.
loss
A064 Terminal box
Check end position sensors
MF1 overload
and pressure guard.
A065 Terminal box
Check warning light,
MF2 overload
buzzer and solenoids.
See chapter 11.5.9 Alarm Log
230754-EN rev.1 2016-12-15