Technical Data - Gardena 7000 Mode D'emploi

Masquer les pouces Voir aussi pour 7000:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
1780-20.960.14_22.08.2011_GARDENA.qxp 22.08.2011 09:36 Seite 17
Problem
Pump doesn't start or
suddenly stops during
operation
Pump runs, but output
suddenly decreases
Only for the submersible
pump 7000 :
Pump does not reach
residual water height of
1 mm during flat suction
In the event of other faults please contact GARDENA Service.
Repairs should only be carried out by GARDENA service centres or dealers
A
authorised by GARDENA.

8. Technical Data

Type
Rated power
Max. delivery capacity
Max. pressure
Max. delivery height
Max. submersion depth
Residual water level
Contaminated water with
particle size of max.
Power cable
Pump connection
Min. water level for operation
Weight approx. (without cable)
Max. media temperature
Mains voltage /
mains frequency
Min./ max. cut-in height
Min./ max. cut-out height
1)
Noise level L
WA
1) Measuring method according to EN 60335 -1
Probable cause
No power.
Dirt particles are jammed
in the suction base.
Suction base is clogged.
The suction base cover
is missing in the suction base.
Submersible Pump
7000 (Art. 1780)
250 W
7,000 l / h
0.6 bar
6 m
7 m
1 mm
5 mm
10 m H05 RNF
universal (G 1 ¹⁄₄ " M) / universal nipple
35 mm
4.3 kg
35 °C
230 V / 50 Hz
180 mm / 680 mm
70 mm / 140 mm
48 dB (A)
Remedy
v Check fuses and electric
connections.
v Disconnect plug and clean
suction base (see
6. Maintenance).
v Disconnect plug and clean
suction base (see
6. Maintenance).
v Disconnect the plug from
the mains and install the
suction base cover (see
6. Maintenance).
Dirty Water Pump
7500 (Art. 1795)
340 W
7,500 l / h
0.6 bar
6 m
7 m
30 mm
25 mm
10 m H05 RNF
55 mm
4.3 kg
35 °C
230 V / 50 Hz
200 mm / 690 mm
65 mm / 150 mm
55 dB (A)
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

750017801795

Table des Matières