Connection of Thermocouples (Summing Confi guration)
16
TC summing configuration
20
TC summing configuration:
Pt 100 4-wire measurement and
thermocouples in non-inverted connection
Note:
You can only connect up to 10 thermocouples in summing
configuration.
You can confi gure all functions of the transmitter using the Paraly SW 111 software.
Wirings with a shaded number can only be adjusted via IrDA.
1
2
3
4
1
2
3
4
Wiring Possibilities
19
TC
21
TC summing configuration:
Pt 100 4-wire measurement and
thermocouples in inverted connection
1
2
3
4
1
2
3
4
47