Error Detection; Technical Data - Waeco PerfectPower PP500 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
Collected_MB-840.qxd
Error
No output voltage
Alarm tone during the operation
Unit switches On/Off cyclically
The inverter switches off when
the power consuming unit is
switched on.
Article No.
Input nominal voltage:
Permanent output capacity (>4 hrs.):
Permanent output capacity (30 min.):
Peak output capacity (0.1 sec.):
Output voltage
Output frequency:
Efficiency with nominal output:
No-load current consumption:
Maximum ambient temperature:
Dimensions W x H x D:
Weight
Subject to changes due to technical progress and availability.
vorbehalten.
Reference! The output voltage of this rectangle inverter can be measured only correctly with an analog
indicator (pointer instrument).
24/06/03
13:03
Page 9

Error detection

Cause
Battery voltage is smaller than
10 V (840-012PP)
or 20 V (840-024PP)
Thermal overload
Fuse is defective (in the inverter
or in the vehicle)
Battery voltage is under
10.7 V (840-012PP)
or 21.4 V (840-024PP)
Poor contact at the battery with
load
Permanent load is too high
Switch-on current is too high

Technical data

10V~15V+/-0.3V
105 x 57 x 225 mm
Troubleshooting
Load battery (start motor)
Switch off power consuming unit
let inverter cool down and
provide for better ventilation
Fuse to be replaced by a
qualified electrician
Charge battery
Cleaning the contacts
Reduce load
Comparison of the unit capacity
with the maximum capacity of
the inverter
840-012PP
400 W
500 W
1000 W
210-230 V AC
50 Hz
90 %
<0.15 A
40°C
1.2 kg
9
840-024PP
20V~30V+/-0.6V
400 W
500 W
1000 W
210-230 V AC
50 Hz
90 %
<0.15 A
40°C
105 x 57 x 225 mm
1.2 kg

Publicité

Table des Matières
loading

Table des Matières