Data Recovering With The Ps Programmer; Adjustment Of Levels - Alcad 905-TO Série Manuel D'installation Et Programmation

Programmateur ps
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 40
'Programming' indicator turns off. The programming indicator will turn off,
the screen of the level meter will come black and after a few seconds the
picture of the selected TV program will be on screen.
8.

DATA RECOVERING WITH THE PS PROGRAMMER

Aiming the transmodulator, press the F and READ keys, and
will be displayed on the screen. All the data programmed in the
transmodulator will be read.
While reading, the program led of the transmodulator will blink; the
transmodulator must not receive other transmissions at the same time.
Keep the PS programmer aimed at the receiver until the
message is deleted from the screen.
To check the recovered data, select the function with the cursor " and !
and the data will be displayed in the PS programmer screen.
9.

ADJUSTMENT OF LEVELS

9.1
Verifying the TO modules
Check that the input COFDM channel hook-up IN indicator (21), the 'correct
MPEG transmodulation' indicator (26) and the 'correct HF output channel '
OUT indicator (27) on the transmodulators are activated.
9.2
Levels of the TO modules
Connect a field measurer to the TEST connector of the PA amplifier, and
verify that the output of said amplifier is charged using a distribution cable
or with a 75 Ω charge, of the RS-275 (cod. 9120011) type. Tune the output
channel measurer of the TO module furthest from the amplifier and verify
that the output level of the TO module is at -0 dB. Tune each of the
remaining TO and adjust the output level of each TO module until reaching
the same level as that in the TO module, which is furthest from the amplifier.
Fig. 13 - Adjusting the levels of the modules
Serie 905-TO
TEST
EXT
OUT
ENG - 33
Read...
Read...

Publicité

Table des Matières
loading

Table des Matières