Setting of the offset
■ ■
pared to the room temperature)
Use a thermometer in order to know the temperature of your room. If the temperature ap-
pearing on the thermostat does not correspond to the real temperature of the room, it is
possible to adjust the offset.
On the thermostat, press the central button during 3 to 5 seconds. The setting menu
appears with the menu 1 figure below.
Adjust the temperature difference with the + and – buttons and press the central
button during 3 seconds.
The offset varies depending on the difference between the two temperatures (e.g. the exa-
mple below).
Example: temperature on the thermometer: 21°C. Temperature on the thermostat: 23°C.
Enter the offset mode and decrease the value on the screen by two units.
Define the defined temperature (comfort/eco/holidays)
■ ■
• Keep pressing on 'SET' to modify every defined temperature with buttons '+' and '-' and
for each mode :
COMFORT
ECO
HOLIDAYS
▶ Advice: you can modify at any time the defined temperature of each mode by repeating the
actions described above.
▶ Advice: press the central button to escape at any time from the 'SET' program.
General settings of the thermostat
■ ■
To enter in the general settings of the thermostat, press a few seconds the central button.
The number in the blackened square indicates the menu number, described below:
1. Setting of the offset (see dedicated paragraph)
2. Maximum possible temperature for the setpoint temperature in "comfort"
3. Minimum possible temperature on "holidays"
8. Activation pilot wire (see dedicated paragraph)
9. Activation time anticipation (see dedicated paragraph)
The menus 7,10 and 11 are not used.
ACTIVATION AND PAIRING
B.
In order that the thermostat communicates with the heater and provides it with correct in-
formation, pairing is required.
On the heater, which was beforehand fixed on the wall and connected to electricity :
■ ■
01.
To switch on the heater, quit the position 0 on the switch based on the backside of the
heater and put it on I
02.
On the thermostat, press the central button during 3 to 5 seconds. The setting menu appears
with the menu 1 figure below.
03.
Press several times the central button to go to the menu 4.
04.
On the heater receiver, press the pairing button. The green indicator light blinks on
the receiver. On the thermostat, validate with '+' then press again the central button.
The green indicator light then stops blinking and remains on. The emitter and receiver are
now paired