Electronic thermic control of the charge with reception of information about the room
temperature and/or outside
Electronic control of the room temperature and weekly timer
Electronic control of the room temperature with open window sensor
Remote control option
Adaptive control of the activation
II. General instructions
Please make sure you read carefully and apply the
following instructions before installing and using your
DECOWATT radiant heater.

SAFETY RECOMMENDATIONS

01. The electrical connection of the device must be
carried out by a qualified electrician.
02. The installation must be protected by a 25 or 30mA
differential circuit breaker (electric safety standard
NFC15-100). The power supply interruption must be
Omni polar (phase and neutral interruption).
03. The DECOWATT radiant heater must be connected
to the power grid (230v AC 50/60 Hz) using a circuit
protected by a 16A overload circuit breaker placed
in an electric switchboard.
04. Make sure you have a mean of disconnection in your
fixed pipelines as per installation rules.
05. The maximum output of a continuously operating
receiver is 2 700 W with no power relay: do not connect
an exceeding power.