Before Use; Indicator And Operating Elements - Berner ISP BWDVC Top Permanent Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
l WARNING!
▶ Use only the brushes supplied with the vacuum device or
defined in the instruction manual. Use of any other brushes
may pose a safety hazard.
▶ Clean and disinfect the vacuum device immediately after use
to prevent microbial contamination due to long-term failure to
clean it, especially when using the device in food-processing.
▶ Do not use any steam jets or high-pressure cleaners for
cleaning.
▶ Acids, acetone and solvents may corrode parts of the vacuum
device.
▶ Do not leave the device without supervision. In case of longer
interruptions of work, pull the power plug.
▶ Do not clean filter cassettes with compressed air

3 Indicator and operating elements

Select from the following functions and settings:
0
Vacuum cleaner is switched off
I
Vacuum cleaner is running
IR
Vacuum cleaner is running
AR
Ready for operation
Automatic shaker function
Fill level indicator *
Speed regulation *
Setting the suction hose diameter *
20 - GB
▶ Have repairs been made only by experts, e. g. the producer's
service. Use original spare parts only.
▶ Improperly repaired devices pose a hazard for the user.

2 Before use

▶ When unpacking, check that the delivery is complete and that
there is no transport damage.
▶ Before using, the operators should be provided with information,
instructions and training for the use of the vacuum cleaner
and the substances that it is to be used for, including the safe
procedure for the removal of the gathered material.
- Plug socket current-conducting
- Plug socket current-conducting
- Automatic shaker function off
- Plug socket current-conducting
- Automatic shaker function on
- Plug socket curren-conducting
- Automatic shaker function on
- The vacuum cleaner is switched on and off via the connected electrical/
compressed air tool* at the plug socket.
- During suction, the folding filter cassettes are cleaned alternately when a
specific negative pressure is reached, at which there is still adequate suction
air.
- When the container is full and/or there is a blockage in the suction hose, the
full indicator lights up. On the M and H vacuum cleaners, an acoustic signal
is also emitted.
- The suction performance can be regulated using the speed regulator.
- Determine the maximum negative pressure for automatic shaking.
(*depending on the equipment variant of your vacuum cleaner)