Section 3 |
• All the 14 bars will be displayed momentarily during booting process
when the remote is switched on. After completion of booting process,
the actual power level will be displayed by the appropriate number of
bars
• When the inverter is supplying no power (is in no load condition) or
lower power below the minimum power display threshold of 50W to
100W, bar graph will not be displayed. Also, the back-light will be dim
• When the power supplied is more than the minimum power display
threshold of 50W to 100W, the 1st bar will appear and the back-light
will brighten. More number of bars will be displayed proportional to
power output level.
INPUT FAULT (3)
noTe: This message will be displayed momentarily (will be
steady) during the boot process when the remote is switched
on. The message will flash during the actual output fault
condition
This message flashes when the inverter has shut down due to the
following (Please read the inverter manual for causes and remedies):
• DC input voltage at the terminals of the inverter is low: 10.5 +/- 0.3V
VDC or lower
• DC input voltage at the inverter terminals is high: 15.3 +/- 0.3V VDC
or higher
• over temperature
OUTPUT FAULT (4)
noTe: This message will be displayed momentarily (will be
steady) during the boot process when the remote is switched on.
The message will flash during the actual output fault condition
This message flashes when the inverter shuts down due to over
load or short circuit on the AC output side (Please read the inverter
manual for causes and remedies):
Display when GFCI has tripped due to leakage on the Load Side
(output side)
The AC output power of the inverter is fed through a Duplex
neMA5-20 outlet with GfCI protection.