Section 3 |
A Green backlit LCD display is used to display operational
parameters and fault conditions. Details of information displayed
are shown at fig 3.1 below:
4
Fig. 3.1 Details of LCD Screen

INPUT VOLTAGE (1)

Input voltage is displayed using 3-digit, 7-segment numerals with 1
decimal:
• Displays 88.8 momentarily during booting process when the remote
is switched on. After completion of booting, the actual value will be
displayed
• Please note that the displayed voltage will be lower than the voltage
at the battery terminals by the amount of voltage drop in the DC side
input wires.

OUTPUT POWER (2)

output power is displayed by a bar graph consisting of 14 gradually
increasing bars for depicting increasing output power level.

DiSPLAY

The backlighting has 2
intensities of brightness –
dim and bright:
• When the inverter is
supplying no power (is
in no load condition) or
1
lower power below the
3
minimum power display
threshold of 50 W to
2
100W, the bar graph will
NOT be displayed. Also,
the back-light will be dim
• When the power supplied
is more than the minimum
power display threshold
of 50W to 100W, the 1st
bar will appear and the
back-light will brighten.
More number of bars will
be displayed proportional
to power output level.
5